summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorDavid Brownell <david-b@pacbell.net>2006-04-03 15:49:04 -0700
committerGreg Kroah-Hartman <gregkh@suse.de>2006-05-16 14:33:57 -0700
commita020ed7521a9737bcf3e34eb880867c60c3c68d0 (patch)
tree52941e00b05df6c1bfe228fd193fdb09cf963d15
parentccf77cc4af5b048e20cfd9327fcc286cb69c34cc (diff)
[PATCH] SPI: busnum == 0 needs to work
We need to be able to have a "SPI bus 0" matching chip numbering; but that number was wrongly used to flag dynamic allocation of a bus number. This patch resolves that issue; now negative numbers trigger dynamic alloc. It also updates the how-to-write-a-controller-driver overview to mention this stuff. Signed-off-by: David Brownell <dbrownell@users.sourceforge.net> Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
-rw-r--r--Documentation/spi/spi-summary34
-rw-r--r--drivers/spi/spi.c4
-rw-r--r--include/linux/spi/spi.h6
3 files changed, 38 insertions, 6 deletions
diff --git a/Documentation/spi/spi-summary b/Documentation/spi/spi-summary
index a5ffba33a35..068732d3227 100644
--- a/Documentation/spi/spi-summary
+++ b/Documentation/spi/spi-summary
@@ -414,7 +414,33 @@ to get the driver-private data allocated for that device.
The driver will initialize the fields of that spi_master, including the
bus number (maybe the same as the platform device ID) and three methods
used to interact with the SPI core and SPI protocol drivers. It will
-also initialize its own internal state.
+also initialize its own internal state. (See below about bus numbering
+and those methods.)
+
+After you initialize the spi_master, then use spi_register_master() to
+publish it to the rest of the system. At that time, device nodes for
+the controller and any predeclared spi devices will be made available,
+and the driver model core will take care of binding them to drivers.
+
+If you need to remove your SPI controller driver, spi_unregister_master()
+will reverse the effect of spi_register_master().
+
+
+BUS NUMBERING
+
+Bus numbering is important, since that's how Linux identifies a given
+SPI bus (shared SCK, MOSI, MISO). Valid bus numbers start at zero. On
+SOC systems, the bus numbers should match the numbers defined by the chip
+manufacturer. For example, hardware controller SPI2 would be bus number 2,
+and spi_board_info for devices connected to it would use that number.
+
+If you don't have such hardware-assigned bus number, and for some reason
+you can't just assign them, then provide a negative bus number. That will
+then be replaced by a dynamically assigned number. You'd then need to treat
+this as a non-static configuration (see above).
+
+
+SPI MASTER METHODS
master->setup(struct spi_device *spi)
This sets up the device clock rate, SPI mode, and word sizes.
@@ -431,6 +457,9 @@ also initialize its own internal state.
state it dynamically associates with that device. If you do that,
be sure to provide the cleanup() method to free that state.
+
+SPI MESSAGE QUEUE
+
The bulk of the driver will be managing the I/O queue fed by transfer().
That queue could be purely conceptual. For example, a driver used only
@@ -440,6 +469,9 @@ But the queue will probably be very real, using message->queue, PIO,
often DMA (especially if the root filesystem is in SPI flash), and
execution contexts like IRQ handlers, tasklets, or workqueues (such
as keventd). Your driver can be as fancy, or as simple, as you need.
+Such a transfer() method would normally just add the message to a
+queue, and then start some asynchronous transfer engine (unless it's
+already running).
THANKS TO
diff --git a/drivers/spi/spi.c b/drivers/spi/spi.c
index 1168ef01588..7a3f733051e 100644
--- a/drivers/spi/spi.c
+++ b/drivers/spi/spi.c
@@ -395,7 +395,7 @@ EXPORT_SYMBOL_GPL(spi_alloc_master);
int __init_or_module
spi_register_master(struct spi_master *master)
{
- static atomic_t dyn_bus_id = ATOMIC_INIT(0);
+ static atomic_t dyn_bus_id = ATOMIC_INIT((1<<16) - 1);
struct device *dev = master->cdev.dev;
int status = -ENODEV;
int dynamic = 0;
@@ -404,7 +404,7 @@ spi_register_master(struct spi_master *master)
return -ENODEV;
/* convention: dynamically assigned bus IDs count down from the max */
- if (master->bus_num == 0) {
+ if (master->bus_num < 0) {
master->bus_num = atomic_dec_return(&dyn_bus_id);
dynamic = 1;
}
diff --git a/include/linux/spi/spi.h b/include/linux/spi/spi.h
index 77add901691..e928c0dcc29 100644
--- a/include/linux/spi/spi.h
+++ b/include/linux/spi/spi.h
@@ -172,13 +172,13 @@ static inline void spi_unregister_driver(struct spi_driver *sdrv)
struct spi_master {
struct class_device cdev;
- /* other than zero (== assign one dynamically), bus_num is fully
+ /* other than negative (== assign one dynamically), bus_num is fully
* board-specific. usually that simplifies to being SOC-specific.
- * example: one SOC has three SPI controllers, numbered 1..3,
+ * example: one SOC has three SPI controllers, numbered 0..2,
* and one board's schematics might show it using SPI-2. software
* would normally use bus_num=2 for that controller.
*/
- u16 bus_num;
+ s16 bus_num;
/* chipselects will be integral to many controllers; some others
* might use board-specific GPIOs.