hwmon: (f75375s) Fix value range for PWM modes
Accepted value range for PWM modes was 0..4, even though only 0..3 is
subsequently used. Limit permitted value range to 0..3 to avoid unpredictable
behavior.
Cc: Riku Voipio <riku.voipio@iki.fi>
Reviewed-by: Bjoern Gerhart <oss@extracloud.de>
Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
-rw-r--r-- | drivers/hwmon/f75375s.c | 2 |
1 files changed, 1 insertions, 1 deletions
diff --git a/drivers/hwmon/f75375s.c b/drivers/hwmon/f75375s.c index 316c29a0b31..777a665164f 100644 --- a/drivers/hwmon/f75375s.c +++ b/drivers/hwmon/f75375s.c @@ -309,7 +309,7 @@ static int set_pwm_enable_direct(struct i2c_client *client, int nr, int val) struct f75375_data *data = i2c_get_clientdata(client); u8 fanmode; - if (val < 0 || val > 4) + if (val < 0 || val > 3) return -EINVAL; fanmode = f75375_read8(client, F75375_REG_FAN_TIMER); |