summaryrefslogtreecommitdiffstats
path: root/Documentation/device-mapper
diff options
context:
space:
mode:
authorJim Ramsay <jim_ramsay@dell.com>2013-07-10 23:41:19 +0100
committerAlasdair G Kergon <agk@redhat.com>2013-07-10 23:41:19 +0100
commit9d0eb0ab432aaa9160cf2675aee73b3900b9bc18 (patch)
tree1efd7430047b501cd9d5c234cc0ef329b39c2bd1 /Documentation/device-mapper
parent8504eed3ac96457addfef7efc6aab2251073e8dc (diff)
dm: add switch target
dm-switch is a new target that maps IO to underlying block devices efficiently when there is a large number of fixed-sized address regions but there is no simple pattern to allow for a compact mapping representation such as dm-stripe. Though we have developed this target for a specific storage device, Dell EqualLogic, we have made an effort to keep it as general purpose as possible in the hope that others may benefit. Originally developed by Jim Ramsay. Simplified by Mikulas Patocka. Signed-off-by: Jim Ramsay <jim_ramsay@dell.com> Signed-off-by: Mikulas Patocka <mpatocka@redhat.com> Signed-off-by: Alasdair G Kergon <agk@redhat.com>
Diffstat (limited to 'Documentation/device-mapper')
-rw-r--r--Documentation/device-mapper/switch.txt126
1 files changed, 126 insertions, 0 deletions
diff --git a/Documentation/device-mapper/switch.txt b/Documentation/device-mapper/switch.txt
new file mode 100644
index 00000000000..2fa749387be
--- /dev/null
+++ b/Documentation/device-mapper/switch.txt
@@ -0,0 +1,126 @@
+dm-switch
+=========
+
+The device-mapper switch target creates a device that supports an
+arbitrary mapping of fixed-size regions of I/O across a fixed set of
+paths. The path used for any specific region can be switched
+dynamically by sending the target a message.
+
+It maps I/O to underlying block devices efficiently when there is a large
+number of fixed-sized address regions but there is no simple pattern
+that would allow for a compact representation of the mapping such as
+dm-stripe.
+
+Background
+----------
+
+Dell EqualLogic and some other iSCSI storage arrays use a distributed
+frameless architecture. In this architecture, the storage group
+consists of a number of distinct storage arrays ("members") each having
+independent controllers, disk storage and network adapters. When a LUN
+is created it is spread across multiple members. The details of the
+spreading are hidden from initiators connected to this storage system.
+The storage group exposes a single target discovery portal, no matter
+how many members are being used. When iSCSI sessions are created, each
+session is connected to an eth port on a single member. Data to a LUN
+can be sent on any iSCSI session, and if the blocks being accessed are
+stored on another member the I/O will be forwarded as required. This
+forwarding is invisible to the initiator. The storage layout is also
+dynamic, and the blocks stored on disk may be moved from member to
+member as needed to balance the load.
+
+This architecture simplifies the management and configuration of both
+the storage group and initiators. In a multipathing configuration, it
+is possible to set up multiple iSCSI sessions to use multiple network
+interfaces on both the host and target to take advantage of the
+increased network bandwidth. An initiator could use a simple round
+robin algorithm to send I/O across all paths and let the storage array
+members forward it as necessary, but there is a performance advantage to
+sending data directly to the correct member.
+
+A device-mapper table already lets you map different regions of a
+device onto different targets. However in this architecture the LUN is
+spread with an address region size on the order of 10s of MBs, which
+means the resulting table could have more than a million entries and
+consume far too much memory.
+
+Using this device-mapper switch target we can now build a two-layer
+device hierarchy:
+
+ Upper Tier – Determine which array member the I/O should be sent to.
+ Lower Tier – Load balance amongst paths to a particular member.
+
+The lower tier consists of a single dm multipath device for each member.
+Each of these multipath devices contains the set of paths directly to
+the array member in one priority group, and leverages existing path
+selectors to load balance amongst these paths. We also build a
+non-preferred priority group containing paths to other array members for
+failover reasons.
+
+The upper tier consists of a single dm-switch device. This device uses
+a bitmap to look up the location of the I/O and choose the appropriate
+lower tier device to route the I/O. By using a bitmap we are able to
+use 4 bits for each address range in a 16 member group (which is very
+large for us). This is a much denser representation than the dm table
+b-tree can achieve.
+
+Construction Parameters
+=======================
+
+ <num_paths> <region_size> <num_optional_args> [<optional_args>...]
+ [<dev_path> <offset>]+
+
+<num_paths>
+ The number of paths across which to distribute the I/O.
+
+<region_size>
+ The number of 512-byte sectors in a region. Each region can be redirected
+ to any of the available paths.
+
+<num_optional_args>
+ The number of optional arguments. Currently, no optional arguments
+ are supported and so this must be zero.
+
+<dev_path>
+ The block device that represents a specific path to the device.
+
+<offset>
+ The offset of the start of data on the specific <dev_path> (in units
+ of 512-byte sectors). This number is added to the sector number when
+ forwarding the request to the specific path. Typically it is zero.
+
+Messages
+========
+
+set_region_mappings <index>:<path_nr> [<index>]:<path_nr> [<index>]:<path_nr>...
+
+Modify the region table by specifying which regions are redirected to
+which paths.
+
+<index>
+ The region number (region size was specified in constructor parameters).
+ If index is omitted, the next region (previous index + 1) is used.
+ Expressed in hexadecimal (WITHOUT any prefix like 0x).
+
+<path_nr>
+ The path number in the range 0 ... (<num_paths> - 1).
+ Expressed in hexadecimal (WITHOUT any prefix like 0x).
+
+Status
+======
+
+No status line is reported.
+
+Example
+=======
+
+Assume that you have volumes vg1/switch0 vg1/switch1 vg1/switch2 with
+the same size.
+
+Create a switch device with 64kB region size:
+ dmsetup create switch --table "0 `blockdev --getsize /dev/vg1/switch0`
+ switch 3 128 0 /dev/vg1/switch0 0 /dev/vg1/switch1 0 /dev/vg1/switch2 0"
+
+Set mappings for the first 7 entries to point to devices switch0, switch1,
+switch2, switch0, switch1, switch2, switch1:
+ dmsetup message switch 0 set_region_mappings 0:0 :1 :2 :0 :1 :2 :1