diff options
author | Linus Torvalds <torvalds@linux-foundation.org> | 2009-09-23 10:11:08 -0700 |
---|---|---|
committer | Linus Torvalds <torvalds@linux-foundation.org> | 2009-09-23 10:11:08 -0700 |
commit | 433c24ed7ff378b22c4d6531a4ce1ffc62642395 (patch) | |
tree | d71181129b05d923100d160ca000f6771fc0ac85 /Documentation/power | |
parent | 85afd82780df133f03185aec7943ee3e0ed56a7b (diff) | |
parent | f056878332a91ed984a116bad4e7d49aefff9e6e (diff) |
Merge git://git.infradead.org/battery-2.6
* git://git.infradead.org/battery-2.6:
power_supply: Add driver for the PMU on WM831x PMICs
ds2760_battery: Fix integer overflow for time_to_empty_now
wm97xx_battery: Convert to dev_pm_ops
wm97xx_battery: Use irq to detect charger state
wm97xx_battery: Use platform_data
wm97xx-core: Pass platform_data to battery
ds2760_battery: implement set_charged() feature
power_supply: get_by_name and set_charged functionality
power_supply: EXPORT_SYMBOL cleanups
ds2760_battery: add current_accum module parameter
ds2760_battery: handle full_active_uAh == 0 case correctly
ds2760_battery: add rated_capacity module parameter
ds2760_battery: export more features
ds2760_battery: delay power supply registration
wm8350_power: Implement charge type property
power_supply: Add a charge_type property, and use it for olpc driver
olpc_battery: Add an 'error' sysfs device that displays raw errors
Revert "power: remove POWER_SUPPLY_PROP_CAPACITY_LEVEL"
Diffstat (limited to 'Documentation/power')
-rw-r--r-- | Documentation/power/power_supply_class.txt | 7 |
1 files changed, 7 insertions, 0 deletions
diff --git a/Documentation/power/power_supply_class.txt b/Documentation/power/power_supply_class.txt index c6cd4956047..9f16c5178b6 100644 --- a/Documentation/power/power_supply_class.txt +++ b/Documentation/power/power_supply_class.txt @@ -76,6 +76,11 @@ STATUS - this attribute represents operating status (charging, full, discharging (i.e. powering a load), etc.). This corresponds to BATTERY_STATUS_* values, as defined in battery.h. +CHARGE_TYPE - batteries can typically charge at different rates. +This defines trickle and fast charges. For batteries that +are already charged or discharging, 'n/a' can be displayed (or +'unknown', if the status is not known). + HEALTH - represents health of the battery, values corresponds to POWER_SUPPLY_HEALTH_*, defined in battery.h. @@ -108,6 +113,8 @@ relative, time-based measurements. ENERGY_FULL, ENERGY_EMPTY - same as above but for energy. CAPACITY - capacity in percents. +CAPACITY_LEVEL - capacity level. This corresponds to +POWER_SUPPLY_CAPACITY_LEVEL_*. TEMP - temperature of the power supply. TEMP_AMBIENT - ambient temperature. |