diff options
author | Jean Delvare <khali@linux-fr.org> | 2010-05-27 19:58:57 +0200 |
---|---|---|
committer | Jean Delvare <khali@linux-fr.org> | 2010-05-27 19:58:57 +0200 |
commit | cff37c9e82e022068840b3d33167e64c6a0ecc06 (patch) | |
tree | 8ebce4d6d8cbc16a661e6548515d02f43d66ad58 /Documentation | |
parent | beb1b6bbf2b448b97b9611200eb4b5a555336c60 (diff) |
hwmon: (tmp102) Various fixes
Fixes from my driver review:
http://lists.lm-sensors.org/pipermail/lm-sensors/2010-March/028051.html
Only the small changes are in there, more important changes will come
later separately as time permits.
* Drop the remnants of the now gone detect function
* The TMP102 has no known compatible chip
* Include the right header files
* Clarify why byte swapping of register values is needed
* Strip resolution info bit from temperature register value
* Set cache lifetime to 1/3 second
* Don't arbitrarily reject limit values; clamp as needed
* Make limit writing unconditional
* Don't check for transaction types the driver doesn't use
* Properly check for error when setting configuration
* Report error on failed probe
* Make the driver load automatically where needed
* Various other minor fixes
Signed-off-by: Jean Delvare <khali@linux-fr.org>
Cc: Steven King <sfking@fdwdc.com>
Diffstat (limited to 'Documentation')
-rw-r--r-- | Documentation/hwmon/tmp102 | 9 |
1 files changed, 4 insertions, 5 deletions
diff --git a/Documentation/hwmon/tmp102 b/Documentation/hwmon/tmp102 index 239dded8539..8454a776312 100644 --- a/Documentation/hwmon/tmp102 +++ b/Documentation/hwmon/tmp102 @@ -4,7 +4,7 @@ Kernel driver tmp102 Supported chips: * Texas Instruments TMP102 Prefix: 'tmp102' - Addresses scanned: I2C 0x48 0x49 0x4a 0x4b + Addresses scanned: none Datasheet: http://focus.ti.com/docs/prod/folders/print/tmp102.html Author: @@ -15,13 +15,12 @@ Description The Texas Instruments TMP102 implements one temperature sensor. Limits can be set through the Overtemperature Shutdown register and Hysteresis register. The -sensor is accurate to 0.5 degrees over the range of -25 to +85 C, and to 1.0 -degrees from -40 to +125 C. Resolution of the sensor is 0.0625 degree. The +sensor is accurate to 0.5 degree over the range of -25 to +85 C, and to 1.0 +degree from -40 to +125 C. Resolution of the sensor is 0.0625 degree. The operating temperature has a minimum of -55 C and a maximum of +150 C. The TMP102 has a programmable update rate that can select between 8, 4, 1, and 0.5 Hz. (Currently the driver only supports the default of 4 Hz). The driver provides the common sysfs-interface for temperatures (see -/Documentation/hwmon/sysfs-interface under Temperatures). - +Documentation/hwmon/sysfs-interface under Temperatures). |