summaryrefslogtreecommitdiffstats
path: root/Documentation
diff options
context:
space:
mode:
authorRoland Stigge <stigge@antcom.de>2011-01-09 09:31:39 -0500
committerGuenter Roeck <guenter.roeck@ericsson.com>2011-01-09 09:10:10 -0800
commit6099469805c24af14250e182bb9ca082b8a6b716 (patch)
tree9b08dd1a10ff89f2557575f5bf95b07babf92beb /Documentation
parent430400b86304ea729ba10f2966a8af67da60a37f (diff)
hwmon: Support for Dallas Semiconductor DS620
Driver for Dallas Semiconductor DS620 temperature sensor and thermostat Signed-off-by: Roland Stigge <stigge@antcom.de> Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com>
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/hwmon/ds62034
1 files changed, 34 insertions, 0 deletions
diff --git a/Documentation/hwmon/ds620 b/Documentation/hwmon/ds620
new file mode 100644
index 00000000000..1fbe3cd916c
--- /dev/null
+++ b/Documentation/hwmon/ds620
@@ -0,0 +1,34 @@
+Kernel driver ds620
+===================
+
+Supported chips:
+ * Dallas Semiconductor DS620
+ Prefix: 'ds620'
+ Datasheet: Publicly available at the Dallas Semiconductor website
+ http://www.dalsemi.com/
+
+Authors:
+ Roland Stigge <stigge@antcom.de>
+ based on ds1621.c by
+ Christian W. Zuckschwerdt <zany@triq.net>
+
+Description
+-----------
+
+The DS620 is a (one instance) digital thermometer and thermostat. It has both
+high and low temperature limits which can be user defined (i.e. programmed
+into non-volatile on-chip registers). Temperature range is -55 degree Celsius
+to +125. Between 0 and 70 degree Celsius, accuracy is 0.5 Kelvin. The value
+returned via sysfs displays post decimal positions.
+
+The thermostat function works as follows: When configured via platform_data
+(struct ds620_platform_data) .pomode == 0 (default), the thermostat output pin
+PO is always low. If .pomode == 1, the thermostat is in PO_LOW mode. I.e., the
+output pin PO becomes active when the temperature falls below temp1_min and
+stays active until the temperature goes above temp1_max.
+
+Likewise, with .pomode == 2, the thermostat is in PO_HIGH mode. I.e., the PO
+output pin becomes active when the temperature goes above temp1_max and stays
+active until the temperature falls below temp1_min.
+
+The PO output pin of the DS620 operates active-low.