summaryrefslogtreecommitdiffstats
path: root/Documentation
diff options
context:
space:
mode:
authorLinus Torvalds <torvalds@linux-foundation.org>2011-09-26 13:35:43 -0700
committerLinus Torvalds <torvalds@linux-foundation.org>2011-09-26 13:35:43 -0700
commitef82bdc57a204bf452da9f7c273c21462f17344e (patch)
treea4e53f30c976a0c7cf224ec5114a210eec177b41 /Documentation
parent231e58e7d9494bddbd05479f9f50ed0be66794d7 (diff)
parent2f1c3db0a6adcfd12d556afa3605d4923658b307 (diff)
Merge branch 'hwmon-for-linus' of git://github.com/groeck/linux
* 'hwmon-for-linus' of git://github.com/groeck/linux: hwmon: (coretemp) remove struct platform_data * parameter from create_core_data() hwmon: (coretemp) constify static data hwmon: (coretemp) don't use kernel assigned CPU number as platform device ID hwmon: (ds620) Fix handling of negative temperatures hwmon: (w83791d) rename prototype parameter from 'register' to 'reg' hwmon: (coretemp) Don't use threshold registers for tempX_max hwmon: (coretemp) Let the user force TjMax hwmon: (coretemp) Drop duplicate function get_pkg_tjmax
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/hwmon/coretemp14
1 files changed, 4 insertions, 10 deletions
diff --git a/Documentation/hwmon/coretemp b/Documentation/hwmon/coretemp
index fa8776ab9b1..84d46c0c71a 100644
--- a/Documentation/hwmon/coretemp
+++ b/Documentation/hwmon/coretemp
@@ -35,13 +35,6 @@ the Out-Of-Spec bit. Following table summarizes the exported sysfs files:
All Sysfs entries are named with their core_id (represented here by 'X').
tempX_input - Core temperature (in millidegrees Celsius).
tempX_max - All cooling devices should be turned on (on Core2).
- Initialized with IA32_THERM_INTERRUPT. When the CPU
- temperature reaches this temperature, an interrupt is
- generated and tempX_max_alarm is set.
-tempX_max_hyst - If the CPU temperature falls below than temperature,
- an interrupt is generated and tempX_max_alarm is reset.
-tempX_max_alarm - Set if the temperature reaches or exceeds tempX_max.
- Reset if the temperature drops to or below tempX_max_hyst.
tempX_crit - Maximum junction temperature (in millidegrees Celsius).
tempX_crit_alarm - Set when Out-of-spec bit is set, never clears.
Correct CPU operation is no longer guaranteed.
@@ -49,9 +42,10 @@ tempX_label - Contains string "Core X", where X is processor
number. For Package temp, this will be "Physical id Y",
where Y is the package number.
-The TjMax temperature is set to 85 degrees C if undocumented model specific
-register (UMSR) 0xee has bit 30 set. If not the TjMax is 100 degrees C as
-(sometimes) documented in processor datasheet.
+On CPU models which support it, TjMax is read from a model-specific register.
+On other models, it is set to an arbitrary value based on weak heuristics.
+If these heuristics don't work for you, you can pass the correct TjMax value
+as a module parameter (tjmax).
Appendix A. Known TjMax lists (TBD):
Some information comes from ark.intel.com