diff options
author | Linus Torvalds <torvalds@linux-foundation.org> | 2014-01-24 17:13:49 -0800 |
---|---|---|
committer | Linus Torvalds <torvalds@linux-foundation.org> | 2014-01-24 17:13:49 -0800 |
commit | 91466574be1a3701fab4abf5ac1539b556575a81 (patch) | |
tree | 89373ef6b0c9e024a9688207b832552dfbcca666 /Documentation | |
parent | 09da8dfa98682d871987145ed11e3232accac860 (diff) | |
parent | c698a4492f01127ca90fc28cd5157f3d616fe4ff (diff) |
Merge branch 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux
Pull thermal management updates from Zhang Rui:
"This time, the biggest change is the work of representing hardware
thermal properties in device tree infrastructure.
This work includes the introduction of a device tree bindings for
describing the hardware thermal behavior and limits, and also a parser
to read and interpret the data, and build thermal zones and thermal
binding parameters. It also contains three examples on how to use the
new representation on sensor devices, using three different drivers to
accomplish it. One driver is in thermal subsystem, the TI SoC
thermal, and the other two drivers are in hwmon subsystem.
Actually, this would be the first step of the complete work because we
still need to check other potential drivers to be converted and then
validate the proposed API. But the reason why I include it in this
pull request is that, first, this change does not hurt any others
without using this approach, second, the principle and concept of this
change would not break after converting the remaining drivers. BTW,
as you can see, there are several points in this change that do not
belong to thermal subsystem. Because it has been suggested by Guenter
R that in such cases, it is recommended to send the complete series
via one single subsystem.
Specifics:
- representing hardware thermal properties in device tree
infrastructure
- fix a regression that the imx thermal driver breaks system suspend.
- introduce ACPI INT3403 thermal driver to retrieve temperature data
from the INT3403 ACPI device object present on some systems.
- introduce debug statement for thermal core and step_wise governor.
- assorted fixes and cleanups for thermal core, cpu cooling, exynos
thrmal, intel powerclamp and imx thermal driver"
* 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux: (34 commits)
thermal: remove const flag from .ops of imx thermal
Thermal: update thermal zone device after setting emul_temp
intel_powerclamp: Fix cstate counter detection.
thermal: imx: add necessary clk operation
Thermal cpu cooling: return error if no valid cpu frequency entry
thermal: fix cpu_cooling max_level behavior
thermal: rcar-thermal: Enable driver compilation with COMPILE_TEST
thermal: debug: add debug statement for core and step_wise
thermal: imx_thermal: add module device table
drivers: thermal: Mark function as static in x86_pkg_temp_thermal.c
thermal:samsung: fix compilation warning
thermal: imx: correct suspend/resume flow
thermal: exynos: fix error return code
Thermal: ACPI INT3403 thermal driver
MAINTAINERS: add thermal bindings entry in thermal domain
arm: dts: make OMAP4460 bandgap node to belong to OCP
arm: dts: make OMAP443x bandgap node to belong to OCP
arm: dts: add cooling properties on omap5 cpu node
arm: dts: add omap5 thermal data
arm: dts: add omap5 CORE thermal data
...
Diffstat (limited to 'Documentation')
3 files changed, 606 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/cpufreq/cpufreq-cpu0.txt b/Documentation/devicetree/bindings/cpufreq/cpufreq-cpu0.txt index 051f764bedb..f055515d2b6 100644 --- a/Documentation/devicetree/bindings/cpufreq/cpufreq-cpu0.txt +++ b/Documentation/devicetree/bindings/cpufreq/cpufreq-cpu0.txt @@ -15,6 +15,10 @@ Optional properties: - clock-latency: Specify the possible maximum transition latency for clock, in unit of nanoseconds. - voltage-tolerance: Specify the CPU voltage tolerance in percentage. +- #cooling-cells: +- cooling-min-level: +- cooling-max-level: + Please refer to Documentation/devicetree/bindings/thermal/thermal.txt. Examples: @@ -33,6 +37,9 @@ cpus { 198000 850000 >; clock-latency = <61036>; /* two CLK32 periods */ + #cooling-cells = <2>; + cooling-min-level = <0>; + cooling-max-level = <2>; }; cpu@1 { diff --git a/Documentation/devicetree/bindings/thermal/imx-thermal.txt b/Documentation/devicetree/bindings/thermal/imx-thermal.txt index 541c25e49ab..1f0f67234a9 100644 --- a/Documentation/devicetree/bindings/thermal/imx-thermal.txt +++ b/Documentation/devicetree/bindings/thermal/imx-thermal.txt @@ -8,10 +8,14 @@ Required properties: calibration data, e.g. OCOTP on imx6q. The details about calibration data can be found in SoC Reference Manual. +Optional properties: +- clocks : thermal sensor's clock source. + Example: tempmon { compatible = "fsl,imx6q-tempmon"; fsl,tempmon = <&anatop>; fsl,tempmon-data = <&ocotp>; + clocks = <&clks 172>; }; diff --git a/Documentation/devicetree/bindings/thermal/thermal.txt b/Documentation/devicetree/bindings/thermal/thermal.txt new file mode 100644 index 00000000000..f5db6b72a36 --- /dev/null +++ b/Documentation/devicetree/bindings/thermal/thermal.txt @@ -0,0 +1,595 @@ +* Thermal Framework Device Tree descriptor + +This file describes a generic binding to provide a way of +defining hardware thermal structure using device tree. +A thermal structure includes thermal zones and their components, +such as trip points, polling intervals, sensors and cooling devices +binding descriptors. + +The target of device tree thermal descriptors is to describe only +the hardware thermal aspects. The thermal device tree bindings are +not about how the system must control or which algorithm or policy +must be taken in place. + +There are five types of nodes involved to describe thermal bindings: +- thermal sensors: devices which may be used to take temperature + measurements. +- cooling devices: devices which may be used to dissipate heat. +- trip points: describe key temperatures at which cooling is recommended. The + set of points should be chosen based on hardware limits. +- cooling maps: used to describe links between trip points and cooling devices; +- thermal zones: used to describe thermal data within the hardware; + +The following is a description of each of these node types. + +* Thermal sensor devices + +Thermal sensor devices are nodes providing temperature sensing capabilities on +thermal zones. Typical devices are I2C ADC converters and bandgaps. These are +nodes providing temperature data to thermal zones. Thermal sensor devices may +control one or more internal sensors. + +Required property: +- #thermal-sensor-cells: Used to provide sensor device specific information + Type: unsigned while referring to it. Typically 0 on thermal sensor + Size: one cell nodes with only one sensor, and at least 1 on nodes + with several internal sensors, in order + to identify uniquely the sensor instances within + the IC. See thermal zone binding for more details + on how consumers refer to sensor devices. + +* Cooling device nodes + +Cooling devices are nodes providing control on power dissipation. There +are essentially two ways to provide control on power dissipation. First +is by means of regulating device performance, which is known as passive +cooling. A typical passive cooling is a CPU that has dynamic voltage and +frequency scaling (DVFS), and uses lower frequencies as cooling states. +Second is by means of activating devices in order to remove +the dissipated heat, which is known as active cooling, e.g. regulating +fan speeds. In both cases, cooling devices shall have a way to determine +the state of cooling in which the device is. + +Any cooling device has a range of cooling states (i.e. different levels +of heat dissipation). For example a fan's cooling states correspond to +the different fan speeds possible. Cooling states are referred to by +single unsigned integers, where larger numbers mean greater heat +dissipation. The precise set of cooling states associated with a device +(as referred to be the cooling-min-state and cooling-max-state +properties) should be defined in a particular device's binding. +For more examples of cooling devices, refer to the example sections below. + +Required properties: +- cooling-min-state: An integer indicating the smallest + Type: unsigned cooling state accepted. Typically 0. + Size: one cell + +- cooling-max-state: An integer indicating the largest + Type: unsigned cooling state accepted. + Size: one cell + +- #cooling-cells: Used to provide cooling device specific information + Type: unsigned while referring to it. Must be at least 2, in order + Size: one cell to specify minimum and maximum cooling state used + in the reference. The first cell is the minimum + cooling state requested and the second cell is + the maximum cooling state requested in the reference. + See Cooling device maps section below for more details + on how consumers refer to cooling devices. + +* Trip points + +The trip node is a node to describe a point in the temperature domain +in which the system takes an action. This node describes just the point, +not the action. + +Required properties: +- temperature: An integer indicating the trip temperature level, + Type: signed in millicelsius. + Size: one cell + +- hysteresis: A low hysteresis value on temperature property (above). + Type: unsigned This is a relative value, in millicelsius. + Size: one cell + +- type: a string containing the trip type. Expected values are: + "active": A trip point to enable active cooling + "passive": A trip point to enable passive cooling + "hot": A trip point to notify emergency + "critical": Hardware not reliable. + Type: string + +* Cooling device maps + +The cooling device maps node is a node to describe how cooling devices +get assigned to trip points of the zone. The cooling devices are expected +to be loaded in the target system. + +Required properties: +- cooling-device: A phandle of a cooling device with its specifier, + Type: phandle + referring to which cooling device is used in this + cooling specifier binding. In the cooling specifier, the first cell + is the minimum cooling state and the second cell + is the maximum cooling state used in this map. +- trip: A phandle of a trip point node within the same thermal + Type: phandle of zone. + trip point node + +Optional property: +- contribution: The cooling contribution to the thermal zone of the + Type: unsigned referred cooling device at the referred trip point. + Size: one cell The contribution is a ratio of the sum + of all cooling contributions within a thermal zone. + +Note: Using the THERMAL_NO_LIMIT (-1UL) constant in the cooling-device phandle +limit specifier means: +(i) - minimum state allowed for minimum cooling state used in the reference. +(ii) - maximum state allowed for maximum cooling state used in the reference. +Refer to include/dt-bindings/thermal/thermal.h for definition of this constant. + +* Thermal zone nodes + +The thermal zone node is the node containing all the required info +for describing a thermal zone, including its cooling device bindings. The +thermal zone node must contain, apart from its own properties, one sub-node +containing trip nodes and one sub-node containing all the zone cooling maps. + +Required properties: +- polling-delay: The maximum number of milliseconds to wait between polls + Type: unsigned when checking this thermal zone. + Size: one cell + +- polling-delay-passive: The maximum number of milliseconds to wait + Type: unsigned between polls when performing passive cooling. + Size: one cell + +- thermal-sensors: A list of thermal sensor phandles and sensor specifier + Type: list of used while monitoring the thermal zone. + phandles + sensor + specifier + +- trips: A sub-node which is a container of only trip point nodes + Type: sub-node required to describe the thermal zone. + +- cooling-maps: A sub-node which is a container of only cooling device + Type: sub-node map nodes, used to describe the relation between trips + and cooling devices. + +Optional property: +- coefficients: An array of integers (one signed cell) containing + Type: array coefficients to compose a linear relation between + Elem size: one cell the sensors listed in the thermal-sensors property. + Elem type: signed Coefficients defaults to 1, in case this property + is not specified. A simple linear polynomial is used: + Z = c0 * x0 + c1 + x1 + ... + c(n-1) * x(n-1) + cn. + + The coefficients are ordered and they match with sensors + by means of sensor ID. Additional coefficients are + interpreted as constant offset. + +Note: The delay properties are bound to the maximum dT/dt (temperature +derivative over time) in two situations for a thermal zone: +(i) - when passive cooling is activated (polling-delay-passive); and +(ii) - when the zone just needs to be monitored (polling-delay) or +when active cooling is activated. + +The maximum dT/dt is highly bound to hardware power consumption and dissipation +capability. The delays should be chosen to account for said max dT/dt, +such that a device does not cross several trip boundaries unexpectedly +between polls. Choosing the right polling delays shall avoid having the +device in temperature ranges that may damage the silicon structures and +reduce silicon lifetime. + +* The thermal-zones node + +The "thermal-zones" node is a container for all thermal zone nodes. It shall +contain only sub-nodes describing thermal zones as in the section +"Thermal zone nodes". The "thermal-zones" node appears under "/". + +* Examples + +Below are several examples on how to use thermal data descriptors +using device tree bindings: + +(a) - CPU thermal zone + +The CPU thermal zone example below describes how to setup one thermal zone +using one single sensor as temperature source and many cooling devices and +power dissipation control sources. + +#include <dt-bindings/thermal/thermal.h> + +cpus { + /* + * Here is an example of describing a cooling device for a DVFS + * capable CPU. The CPU node describes its four OPPs. + * The cooling states possible are 0..3, and they are + * used as OPP indexes. The minimum cooling state is 0, which means + * all four OPPs can be available to the system. The maximum + * cooling state is 3, which means only the lowest OPPs (198MHz@0.85V) + * can be available in the system. + */ + cpu0: cpu@0 { + ... + operating-points = < + /* kHz uV */ + 970000 1200000 + 792000 1100000 + 396000 950000 + 198000 850000 + >; + cooling-min-state = <0>; + cooling-max-state = <3>; + #cooling-cells = <2>; /* min followed by max */ + }; + ... +}; + +&i2c1 { + ... + /* + * A simple fan controller which supports 10 speeds of operation + * (represented as 0-9). + */ + fan0: fan@0x48 { + ... + cooling-min-state = <0>; + cooling-max-state = <9>; + #cooling-cells = <2>; /* min followed by max */ + }; +}; + +ocp { + ... + /* + * A simple IC with a single bandgap temperature sensor. + */ + bandgap0: bandgap@0x0000ED00 { + ... + #thermal-sensor-cells = <0>; + }; +}; + +thermal-zones { + cpu-thermal: cpu-thermal { + polling-delay-passive = <250>; /* milliseconds */ + polling-delay = <1000>; /* milliseconds */ + + thermal-sensors = <&bandgap0>; + + trips { + cpu-alert0: cpu-alert { + temperature = <90000>; /* millicelsius */ + hysteresis = <2000>; /* millicelsius */ + type = "active"; + }; + cpu-alert1: cpu-alert { + temperature = <100000>; /* millicelsius */ + hysteresis = <2000>; /* millicelsius */ + type = "passive"; + }; + cpu-crit: cpu-crit { + temperature = <125000>; /* millicelsius */ + hysteresis = <2000>; /* millicelsius */ + type = "critical"; + }; + }; + + cooling-maps { + map0 { + trip = <&cpu-alert0>; + cooling-device = <&fan0 THERMAL_NO_LIMITS 4>; + }; + map1 { + trip = <&cpu-alert1>; + cooling-device = <&fan0 5 THERMAL_NO_LIMITS>; + }; + map2 { + trip = <&cpu-alert1>; + cooling-device = + <&cpu0 THERMAL_NO_LIMITS THERMAL_NO_LIMITS>; + }; + }; + }; +}; + +In the example above, the ADC sensor (bandgap0) at address 0x0000ED00 is +used to monitor the zone 'cpu-thermal' using its sole sensor. A fan +device (fan0) is controlled via I2C bus 1, at address 0x48, and has ten +different cooling states 0-9. It is used to remove the heat out of +the thermal zone 'cpu-thermal' using its cooling states +from its minimum to 4, when it reaches trip point 'cpu-alert0' +at 90C, as an example of active cooling. The same cooling device is used at +'cpu-alert1', but from 5 to its maximum state. The cpu@0 device is also +linked to the same thermal zone, 'cpu-thermal', as a passive cooling device, +using all its cooling states at trip point 'cpu-alert1', +which is a trip point at 100C. On the thermal zone 'cpu-thermal', at the +temperature of 125C, represented by the trip point 'cpu-crit', the silicon +is not reliable anymore. + +(b) - IC with several internal sensors + +The example below describes how to deploy several thermal zones based off a +single sensor IC, assuming it has several internal sensors. This is a common +case on SoC designs with several internal IPs that may need different thermal +requirements, and thus may have their own sensor to monitor or detect internal +hotspots in their silicon. + +#include <dt-bindings/thermal/thermal.h> + +ocp { + ... + /* + * A simple IC with several bandgap temperature sensors. + */ + bandgap0: bandgap@0x0000ED00 { + ... + #thermal-sensor-cells = <1>; + }; +}; + +thermal-zones { + cpu-thermal: cpu-thermal { + polling-delay-passive = <250>; /* milliseconds */ + polling-delay = <1000>; /* milliseconds */ + + /* sensor ID */ + thermal-sensors = <&bandgap0 0>; + + trips { + /* each zone within the SoC may have its own trips */ + cpu-alert: cpu-alert { + temperature = <100000>; /* millicelsius */ + hysteresis = <2000>; /* millicelsius */ + type = "passive"; + }; + cpu-crit: cpu-crit { + temperature = <125000>; /* millicelsius */ + hysteresis = <2000>; /* millicelsius */ + type = "critical"; + }; + }; + + cooling-maps { + /* each zone within the SoC may have its own cooling */ + ... + }; + }; + + gpu-thermal: gpu-thermal { + polling-delay-passive = <120>; /* milliseconds */ + polling-delay = <1000>; /* milliseconds */ + + /* sensor ID */ + thermal-sensors = <&bandgap0 1>; + + trips { + /* each zone within the SoC may have its own trips */ + gpu-alert: gpu-alert { + temperature = <90000>; /* millicelsius */ + hysteresis = <2000>; /* millicelsius */ + type = "passive"; + }; + gpu-crit: gpu-crit { + temperature = <105000>; /* millicelsius */ + hysteresis = <2000>; /* millicelsius */ + type = "critical"; + }; + }; + + cooling-maps { + /* each zone within the SoC may have its own cooling */ + ... + }; + }; + + dsp-thermal: dsp-thermal { + polling-delay-passive = <50>; /* milliseconds */ + polling-delay = <1000>; /* milliseconds */ + + /* sensor ID */ + thermal-sensors = <&bandgap0 2>; + + trips { + /* each zone within the SoC may have its own trips */ + dsp-alert: gpu-alert { + temperature = <90000>; /* millicelsius */ + hysteresis = <2000>; /* millicelsius */ + type = "passive"; + }; + dsp-crit: gpu-crit { + temperature = <135000>; /* millicelsius */ + hysteresis = <2000>; /* millicelsius */ + type = "critical"; + }; + }; + + cooling-maps { + /* each zone within the SoC may have its own cooling */ + ... + }; + }; +}; + +In the example above, there is one bandgap IC which has the capability to +monitor three sensors. The hardware has been designed so that sensors are +placed on different places in the DIE to monitor different temperature +hotspots: one for CPU thermal zone, one for GPU thermal zone and the +other to monitor a DSP thermal zone. + +Thus, there is a need to assign each sensor provided by the bandgap IC +to different thermal zones. This is achieved by means of using the +#thermal-sensor-cells property and using the first cell of the sensor +specifier as sensor ID. In the example, then, <bandgap 0> is used to +monitor CPU thermal zone, <bandgap 1> is used to monitor GPU thermal +zone and <bandgap 2> is used to monitor DSP thermal zone. Each zone +may be uncorrelated, having its own dT/dt requirements, trips +and cooling maps. + + +(c) - Several sensors within one single thermal zone + +The example below illustrates how to use more than one sensor within +one thermal zone. + +#include <dt-bindings/thermal/thermal.h> + +&i2c1 { + ... + /* + * A simple IC with a single temperature sensor. + */ + adc: sensor@0x49 { + ... + #thermal-sensor-cells = <0>; + }; +}; + +ocp { + ... + /* + * A simple IC with a single bandgap temperature sensor. + */ + bandgap0: bandgap@0x0000ED00 { + ... + #thermal-sensor-cells = <0>; + }; +}; + +thermal-zones { + cpu-thermal: cpu-thermal { + polling-delay-passive = <250>; /* milliseconds */ + polling-delay = <1000>; /* milliseconds */ + + thermal-sensors = <&bandgap0>, /* cpu */ + <&adc>; /* pcb north */ + + /* hotspot = 100 * bandgap - 120 * adc + 484 */ + coefficients = <100 -120 484>; + + trips { + ... + }; + + cooling-maps { + ... + }; + }; +}; + +In some cases, there is a need to use more than one sensor to extrapolate +a thermal hotspot in the silicon. The above example illustrates this situation. +For instance, it may be the case that a sensor external to CPU IP may be placed +close to CPU hotspot and together with internal CPU sensor, it is used +to determine the hotspot. Assuming this is the case for the above example, +the hypothetical extrapolation rule would be: + hotspot = 100 * bandgap - 120 * adc + 484 + +In other context, the same idea can be used to add fixed offset. For instance, +consider the hotspot extrapolation rule below: + hotspot = 1 * adc + 6000 + +In the above equation, the hotspot is always 6C higher than what is read +from the ADC sensor. The binding would be then: + thermal-sensors = <&adc>; + + /* hotspot = 1 * adc + 6000 */ + coefficients = <1 6000>; + +(d) - Board thermal + +The board thermal example below illustrates how to setup one thermal zone +with many sensors and many cooling devices. + +#include <dt-bindings/thermal/thermal.h> + +&i2c1 { + ... + /* + * An IC with several temperature sensor. + */ + adc-dummy: sensor@0x50 { + ... + #thermal-sensor-cells = <1>; /* sensor internal ID */ + }; +}; + +thermal-zones { + batt-thermal { + polling-delay-passive = <500>; /* milliseconds */ + polling-delay = <2500>; /* milliseconds */ + + /* sensor ID */ + thermal-sensors = <&adc-dummy 4>; + + trips { + ... + }; + + cooling-maps { + ... + }; + }; + + board-thermal: board-thermal { + polling-delay-passive = <1000>; /* milliseconds */ + polling-delay = <2500>; /* milliseconds */ + + /* sensor ID */ + thermal-sensors = <&adc-dummy 0>, /* pcb top edge */ + <&adc-dummy 1>, /* lcd */ + <&adc-dymmy 2>; /* back cover */ + /* + * An array of coefficients describing the sensor + * linear relation. E.g.: + * z = c1*x1 + c2*x2 + c3*x3 + */ + coefficients = <1200 -345 890>; + + trips { + /* Trips are based on resulting linear equation */ + cpu-trip: cpu-trip { + temperature = <60000>; /* millicelsius */ + hysteresis = <2000>; /* millicelsius */ + type = "passive"; + }; + gpu-trip: gpu-trip { + temperature = <55000>; /* millicelsius */ + hysteresis = <2000>; /* millicelsius */ + type = "passive"; + } + lcd-trip: lcp-trip { + temperature = <53000>; /* millicelsius */ + hysteresis = <2000>; /* millicelsius */ + type = "passive"; + }; + crit-trip: crit-trip { + temperature = <68000>; /* millicelsius */ + hysteresis = <2000>; /* millicelsius */ + type = "critical"; + }; + }; + + cooling-maps { + map0 { + trip = <&cpu-trip>; + cooling-device = <&cpu0 0 2>; + contribution = <55>; + }; + map1 { + trip = <&gpu-trip>; + cooling-device = <&gpu0 0 2>; + contribution = <20>; + }; + map2 { + trip = <&lcd-trip>; + cooling-device = <&lcd0 5 10>; + contribution = <15>; + }; + }; + }; +}; + +The above example is a mix of previous examples, a sensor IP with several internal +sensors used to monitor different zones, one of them is composed by several sensors and +with different cooling devices. |