diff options
author | Soren Brinkmann <soren.brinkmann@xilinx.com> | 2013-11-26 17:04:48 -0800 |
---|---|---|
committer | Michal Simek <michal.simek@xilinx.com> | 2013-12-12 09:50:21 +0100 |
commit | 204accaf18d84dd9dc4a98f37c82053f79b9b931 (patch) | |
tree | f5bb15f381765ab3b6dfb9755ead6e44814262e7 /arch/arm | |
parent | 982264c3e0bf52e81a2c2b908a81ab0e9b422f32 (diff) |
arm: dt: zynq: Remove 'clock-ranges' from TTC nodes
The bindings for the TTC changed in commit 'arm: zynq: Use standard
timer binding' (e932900a3279b5dbb6d8f43c7b369003620e137c). That change
removed possible subnodes from this driver rendering the 'clock-ranges'
property invalid for this node.
Signed-off-by: Soren Brinkmann <soren.brinkmann@xilinx.com>
Acked-by: Peter Crosthwaite <peter.crosthwaite@xilinx.com>
Acked-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Signed-off-by: Michal Simek <michal.simek@xilinx.com>
Diffstat (limited to 'arch/arm')
-rw-r--r-- | arch/arm/boot/dts/zynq-7000.dtsi | 2 |
1 files changed, 0 insertions, 2 deletions
diff --git a/arch/arm/boot/dts/zynq-7000.dtsi b/arch/arm/boot/dts/zynq-7000.dtsi index aebc48d8c39..3ea27e44b82 100644 --- a/arch/arm/boot/dts/zynq-7000.dtsi +++ b/arch/arm/boot/dts/zynq-7000.dtsi @@ -124,7 +124,6 @@ compatible = "cdns,ttc"; clocks = <&clkc 6>; reg = <0xF8001000 0x1000>; - clock-ranges; }; ttc1: ttc1@f8002000 { @@ -133,7 +132,6 @@ compatible = "cdns,ttc"; clocks = <&clkc 6>; reg = <0xF8002000 0x1000>; - clock-ranges; }; scutimer: scutimer@f8f00600 { interrupt-parent = <&intc>; |