summaryrefslogtreecommitdiffstats
path: root/arch/powerpc/kvm/book3s_pr.c
diff options
context:
space:
mode:
authorAlexander Graf <agraf@suse.de>2012-08-12 11:34:21 +0200
committerAlexander Graf <agraf@suse.de>2012-10-05 23:38:44 +0200
commit0652eaaebea0995b3236e51dec727d62264f4248 (patch)
tree31c87156d9e61a6de5ba9578f95d1936951e66cf /arch/powerpc/kvm/book3s_pr.c
parent706fb730cb4f9db2e3de33391475dd0616c2c935 (diff)
KVM: PPC: Book3S: PR: Indicate we're out of guest mode
When going out of guest mode, indicate that we are in vcpu->mode. That way requests from other CPUs don't needlessly need to kick us to process them, because it'll just happen next time we enter the guest. Signed-off-by: Alexander Graf <agraf@suse.de>
Diffstat (limited to 'arch/powerpc/kvm/book3s_pr.c')
-rw-r--r--arch/powerpc/kvm/book3s_pr.c1
1 files changed, 1 insertions, 0 deletions
diff --git a/arch/powerpc/kvm/book3s_pr.c b/arch/powerpc/kvm/book3s_pr.c
index b4ae11ec068..9430a362e5a 100644
--- a/arch/powerpc/kvm/book3s_pr.c
+++ b/arch/powerpc/kvm/book3s_pr.c
@@ -1152,6 +1152,7 @@ int kvmppc_vcpu_run(struct kvm_run *kvm_run, struct kvm_vcpu *vcpu)
#endif
out:
+ vcpu->mode = OUTSIDE_GUEST_MODE;
preempt_enable();
return ret;
}