summaryrefslogtreecommitdiffstats
path: root/drivers/hid/hid-uclogic.c
diff options
context:
space:
mode:
authorNikolai Kondrashov <spbnick@gmail.com>2012-03-06 09:54:22 +0200
committerJiri Kosina <jkosina@suse.cz>2012-03-06 11:20:54 +0100
commit51153a78dfd090529472735ba1a4e7f50ac7542f (patch)
treea0e490584a7a88bba654015db71dc4e4efaaf59f /drivers/hid/hid-uclogic.c
parent22ca20b250f5c9672a53b34f032f43dd2c4a4aaf (diff)
HID: uclogic: Replace original rdescs with links
Replace original report descriptor dumps in the comments with links to tablet descriptions in a wiki, to make code clearer. Signed-off-by: Nikolai Kondrashov <spbnick@gmail.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Diffstat (limited to 'drivers/hid/hid-uclogic.c')
-rw-r--r--drivers/hid/hid-uclogic.c413
1 files changed, 11 insertions, 402 deletions
diff --git a/drivers/hid/hid-uclogic.c b/drivers/hid/hid-uclogic.c
index e15732f1a22..1f112891033 100644
--- a/drivers/hid/hid-uclogic.c
+++ b/drivers/hid/hid-uclogic.c
@@ -18,141 +18,16 @@
#include "hid-ids.h"
/*
- * The original descriptors of WPXXXXU tablets have three report IDs, of
- * which only two are used (8 and 9), and the remaining (7) seems to have
- * the originally intended pen description which was abandoned for some
- * reason. From this unused description it is possible to extract the
- * actual physical extents and resolution. All the models use the same
- * descriptor with different extents for the unused report ID.
- *
- * Here it is:
- *
- * Usage Page (Digitizer), ; Digitizer (0Dh)
- * Usage (Pen), ; Pen (02h, application collection)
- * Collection (Application),
- * Report ID (7),
- * Usage (Stylus), ; Stylus (20h, logical collection)
- * Collection (Physical),
- * Usage (Tip Switch), ; Tip switch (42h, momentary control)
- * Usage (Barrel Switch), ; Barrel switch (44h, momentary control)
- * Usage (Eraser), ; Eraser (45h, momentary control)
- * Logical Minimum (0),
- * Logical Maximum (1),
- * Report Size (1),
- * Report Count (3),
- * Input (Variable),
- * Report Count (3),
- * Input (Constant, Variable),
- * Usage (In Range), ; In range (32h, momentary control)
- * Report Count (1),
- * Input (Variable),
- * Report Count (1),
- * Input (Constant, Variable),
- * Usage Page (Desktop), ; Generic desktop controls (01h)
- * Usage (X), ; X (30h, dynamic value)
- * Report Size (16),
- * Report Count (1),
- * Push,
- * Unit Exponent (13),
- * Unit (Inch^3),
- * Physical Minimum (0),
- * Physical Maximum (Xpm),
- * Logical Maximum (Xlm),
- * Input (Variable),
- * Usage (Y), ; Y (31h, dynamic value)
- * Physical Maximum (Ypm),
- * Logical Maximum (Ylm),
- * Input (Variable),
- * Pop,
- * Usage Page (Digitizer), ; Digitizer (0Dh)
- * Usage (Tip Pressure), ; Tip pressure (30h, dynamic value)
- * Logical Maximum (1023),
- * Input (Variable),
- * Report Size (16),
- * End Collection,
- * End Collection,
- * Usage Page (Desktop), ; Generic desktop controls (01h)
- * Usage (Mouse), ; Mouse (02h, application collection)
- * Collection (Application),
- * Report ID (8),
- * Usage (Pointer), ; Pointer (01h, physical collection)
- * Collection (Physical),
- * Usage Page (Button), ; Button (09h)
- * Usage Minimum (01h),
- * Usage Maximum (03h),
- * Logical Minimum (0),
- * Logical Maximum (1),
- * Report Count (3),
- * Report Size (1),
- * Input (Variable),
- * Report Count (5),
- * Input (Constant),
- * Usage Page (Desktop), ; Generic desktop controls (01h)
- * Usage (X), ; X (30h, dynamic value)
- * Usage (Y), ; Y (31h, dynamic value)
- * Usage (Wheel), ; Wheel (38h, dynamic value)
- * Usage (00h),
- * Logical Minimum (-127),
- * Logical Maximum (127),
- * Report Size (8),
- * Report Count (4),
- * Input (Variable, Relative),
- * End Collection,
- * End Collection,
- * Usage Page (Desktop), ; Generic desktop controls (01h)
- * Usage (Mouse), ; Mouse (02h, application collection)
- * Collection (Application),
- * Report ID (9),
- * Usage (Pointer), ; Pointer (01h, physical collection)
- * Collection (Physical),
- * Usage Page (Button), ; Button (09h)
- * Usage Minimum (01h),
- * Usage Maximum (03h),
- * Logical Minimum (0),
- * Logical Maximum (1),
- * Report Count (3),
- * Report Size (1),
- * Input (Variable),
- * Report Count (5),
- * Input (Constant),
- * Usage Page (Desktop), ; Generic desktop controls (01h)
- * Usage (X), ; X (30h, dynamic value)
- * Usage (Y), ; Y (31h, dynamic value)
- * Logical Minimum (0),
- * Logical Maximum (32767),
- * Physical Minimum (0),
- * Physical Maximum (32767),
- * Report Count (2),
- * Report Size (16),
- * Input (Variable),
- * Usage Page (Digitizer), ; Digitizer (0Dh)
- * Usage (Tip Pressure), ; Tip pressure (30h, dynamic value)
- * Logical Maximum (1023),
- * Report Count (1),
- * Report Size (16),
- * Input (Variable),
- * End Collection,
- * End Collection
- *
- * Here are the extents values for the WPXXXXU models:
- *
- * Xpm Xlm Ypm Ylm
- * WP4030U 4000 8000 3000 6000
- * WP5540U 5500 11000 4000 8000
- * WP8060U 8000 16000 6000 12000
- *
- * This suggests that all of them have 2000 LPI resolution, as advertised.
+ * See WPXXXXU model descriptions, device and HID report descriptors at
+ * http://sf.net/apps/mediawiki/digimend/?title=UC-Logic_Tablet_WP4030U
+ * http://sf.net/apps/mediawiki/digimend/?title=UC-Logic_Tablet_WP5540U
+ * http://sf.net/apps/mediawiki/digimend/?title=UC-Logic_Tablet_WP8060U
*/
/* Size of the original descriptor of WPXXXXU tablets */
#define WPXXXXU_RDESC_ORIG_SIZE 212
-/*
- * Fixed WP4030U report descriptor.
- * Although the hardware might actually support it, the mouse description
- * has been removed, since there seems to be no devices having one and it
- * wouldn't make much sense because of the working area size.
- */
+/* Fixed WP4030U report descriptor */
static __u8 wp4030u_rdesc_fixed[] = {
0x05, 0x0D, /* Usage Page (Digitizer), */
0x09, 0x02, /* Usage (Pen), */
@@ -343,148 +218,14 @@ static __u8 wp8060u_rdesc_fixed[] = {
};
/*
- * Original WP1062 report descriptor.
- *
- * Only report ID 9 is actually used.
- *
- * Usage Page (Digitizer), ; Digitizer (0Dh)
- * Usage (Pen), ; Pen (02h, application collection)
- * Collection (Application),
- * Report ID (7),
- * Usage (Stylus), ; Stylus (20h, logical collection)
- * Collection (Physical),
- * Usage (Tip Switch), ; Tip switch (42h, momentary control)
- * Usage (Barrel Switch), ; Barrel switch (44h, momentary control)
- * Usage (Eraser), ; Eraser (45h, momentary control)
- * Logical Minimum (0),
- * Logical Maximum (1),
- * Report Size (1),
- * Report Count (3),
- * Input (Variable),
- * Report Count (3),
- * Input (Constant, Variable),
- * Usage (In Range), ; In range (32h, momentary control)
- * Report Count (1),
- * Input (Variable),
- * Report Count (1),
- * Input (Constant, Variable),
- * Usage Page (Desktop), ; Generic desktop controls (01h)
- * Usage (X), ; X (30h, dynamic value)
- * Report Size (16),
- * Report Count (1),
- * Push,
- * Unit Exponent (13),
- * Unit (Inch),
- * Physical Minimum (0),
- * Physical Maximum (10000),
- * Logical Maximum (20000),
- * Input (Variable),
- * Usage (Y), ; Y (31h, dynamic value)
- * Physical Maximum (6583),
- * Logical Maximum (13166),
- * Input (Variable),
- * Pop,
- * Usage Page (Digitizer), ; Digitizer (0Dh)
- * Usage (Tip Pressure), ; Tip pressure (30h, dynamic value)
- * Logical Maximum (1023),
- * Input (Variable),
- * Report Size (16),
- * End Collection,
- * End Collection,
- * Usage Page (Desktop), ; Generic desktop controls (01h)
- * Usage (Mouse), ; Mouse (02h, application collection)
- * Collection (Application),
- * Report ID (8),
- * Usage (Pointer), ; Pointer (01h, physical collection)
- * Collection (Physical),
- * Usage Page (Button), ; Button (09h)
- * Usage Minimum (01h),
- * Usage Maximum (03h),
- * Logical Minimum (0),
- * Logical Maximum (1),
- * Report Count (3),
- * Report Size (1),
- * Input (Variable),
- * Report Count (5),
- * Input (Constant),
- * Usage Page (Desktop), ; Generic desktop controls (01h)
- * Usage (X), ; X (30h, dynamic value)
- * Usage (Y), ; Y (31h, dynamic value)
- * Usage (Wheel), ; Wheel (38h, dynamic value)
- * Usage (00h),
- * Logical Minimum (-127),
- * Logical Maximum (127),
- * Report Size (8),
- * Report Count (4),
- * Input (Variable, Relative),
- * End Collection,
- * End Collection,
- * Usage Page (Desktop), ; Generic desktop controls (01h)
- * Usage (Mouse), ; Mouse (02h, application collection)
- * Collection (Application),
- * Report ID (9),
- * Usage (Pointer), ; Pointer (01h, physical collection)
- * Collection (Physical),
- * Usage Page (Button), ; Button (09h)
- * Usage Minimum (01h),
- * Usage Maximum (03h),
- * Logical Minimum (0),
- * Logical Maximum (1),
- * Report Count (3),
- * Report Size (1),
- * Input (Variable),
- * Report Count (4),
- * Input (Constant),
- * Usage Page (Digitizer), ; Digitizer (0Dh)
- * Usage (In Range), ; In range (32h, momentary control)
- * Report Count (1),
- * Input (Variable),
- * Usage Page (Desktop), ; Generic desktop controls (01h)
- * Usage (X), ; X (30h, dynamic value)
- * Report Size (16),
- * Report Count (1),
- * Push,
- * Unit Exponent (13),
- * Unit (Inch),
- * Physical Minimum (0),
- * Physical Maximum (10000),
- * Logical Maximum (20000),
- * Input (Variable),
- * Usage (Y), ; Y (31h, dynamic value)
- * Physical Maximum (6583),
- * Logical Maximum (13166),
- * Input (Variable),
- * Pop,
- * Usage Page (Digitizer), ; Digitizer (0Dh)
- * Usage (Tip Pressure), ; Tip pressure (30h, dynamic value)
- * Logical Maximum (1023),
- * Report Count (1),
- * Report Size (16),
- * Input (Variable),
- * End Collection,
- * End Collection,
- * Usage Page (Desktop), ; Generic desktop controls (01h)
- * Usage (00h),
- * Collection (Application),
- * Report ID (4),
- * Logical Minimum (0),
- * Logical Maximum (255),
- * Usage (00h),
- * Report Size (8),
- * Report Count (3),
- * Feature (Variable),
- * End Collection
+ * See WP1062 description, device and HID report descriptors at
+ * http://sf.net/apps/mediawiki/digimend/?title=UC-Logic_Tablet_WP1062
*/
/* Size of the original descriptor of WP1062 tablet */
#define WP1062_RDESC_ORIG_SIZE 254
-/*
- * Fixed WP1062 report descriptor.
- *
- * Removed unused reports, corrected second barrel button usage code, physical
- * units.
- */
+/* Fixed WP1062 report descriptor */
static __u8 wp1062_rdesc_fixed[] = {
0x05, 0x0D, /* Usage Page (Digitizer), */
0x09, 0x02, /* Usage (Pen), */
@@ -530,146 +271,14 @@ static __u8 wp1062_rdesc_fixed[] = {
};
/*
- * Original PF1209 report descriptor.
- *
- * The descriptor is similar to WPXXXXU descriptors, with an addition of a
- * feature report (ID 4) of unknown purpose.
- *
- * Although the advertised resolution is 4000 LPI the unused report ID
- * (taken from WPXXXXU, it seems) states 2000 LPI, but it is probably
- * incorrect and is a result of blind copying without understanding. Anyway
- * the real logical extents are always scaled to 0..32767, which IMHO spoils
- * the precision.
- *
- * Usage Page (Digitizer), ; Digitizer (0Dh)
- * Usage (Pen), ; Pen (02h, application collection)
- * Collection (Application),
- * Report ID (7),
- * Usage (Stylus), ; Stylus (20h, logical collection)
- * Collection (Physical),
- * Usage (Tip Switch), ; Tip switch (42h, momentary control)
- * Usage (Barrel Switch), ; Barrel switch (44h, momentary control)
- * Usage (Eraser), ; Eraser (45h, momentary control)
- * Logical Minimum (0),
- * Logical Maximum (1),
- * Report Size (1),
- * Report Count (3),
- * Input (Variable),
- * Report Count (3),
- * Input (Constant, Variable),
- * Usage (In Range), ; In range (32h, momentary control)
- * Report Count (1),
- * Input (Variable),
- * Report Count (1),
- * Input (Constant, Variable),
- * Usage Page (Desktop), ; Generic desktop controls (01h)
- * Usage (X), ; X (30h, dynamic value)
- * Report Size (16),
- * Report Count (1),
- * Push,
- * Unit Exponent (13),
- * Unit (Inch^3),
- * Physical Minimum (0),
- * Physical Maximum (12000),
- * Logical Maximum (24000),
- * Input (Variable),
- * Usage (Y), ; Y (31h, dynamic value)
- * Physical Maximum (9000),
- * Logical Maximum (18000),
- * Input (Variable),
- * Pop,
- * Usage Page (Digitizer), ; Digitizer (0Dh)
- * Usage (Tip Pressure), ; Tip pressure (30h, dynamic value)
- * Logical Maximum (1023),
- * Input (Variable),
- * Report Size (16),
- * End Collection,
- * End Collection,
- * Usage Page (Desktop), ; Generic desktop controls (01h)
- * Usage (Mouse), ; Mouse (02h, application collection)
- * Collection (Application),
- * Report ID (8),
- * Usage (Pointer), ; Pointer (01h, physical collection)
- * Collection (Physical),
- * Usage Page (Button), ; Button (09h)
- * Usage Minimum (01h),
- * Usage Maximum (03h),
- * Logical Minimum (0),
- * Logical Maximum (1),
- * Report Count (3),
- * Report Size (1),
- * Input (Variable),
- * Report Count (5),
- * Input (Constant),
- * Usage Page (Desktop), ; Generic desktop controls (01h)
- * Usage (X), ; X (30h, dynamic value)
- * Usage (Y), ; Y (31h, dynamic value)
- * Usage (Wheel), ; Wheel (38h, dynamic value)
- * Usage (00h),
- * Logical Minimum (-127),
- * Logical Maximum (127),
- * Report Size (8),
- * Report Count (4),
- * Input (Variable, Relative),
- * End Collection,
- * End Collection,
- * Usage Page (Desktop), ; Generic desktop controls (01h)
- * Usage (Mouse), ; Mouse (02h, application collection)
- * Collection (Application),
- * Report ID (9),
- * Usage (Pointer), ; Pointer (01h, physical collection)
- * Collection (Physical),
- * Usage Page (Button), ; Button (09h)
- * Usage Minimum (01h),
- * Usage Maximum (03h),
- * Logical Minimum (0),
- * Logical Maximum (1),
- * Report Count (3),
- * Report Size (1),
- * Input (Variable),
- * Report Count (5),
- * Input (Constant),
- * Usage Page (Desktop), ; Generic desktop controls (01h)
- * Usage (X), ; X (30h, dynamic value)
- * Usage (Y), ; Y (31h, dynamic value)
- * Logical Minimum (0),
- * Logical Maximum (32767),
- * Physical Minimum (0),
- * Physical Maximum (32767),
- * Report Count (2),
- * Report Size (16),
- * Input (Variable),
- * Usage Page (Digitizer), ; Digitizer (0Dh)
- * Usage (Tip Pressure), ; Tip pressure (30h, dynamic value)
- * Logical Maximum (1023),
- * Report Count (1),
- * Report Size (16),
- * Input (Variable),
- * End Collection,
- * End Collection,
- * Usage Page (Desktop), ; Generic desktop controls (01h)
- * Usage (00h),
- * Collection (Application),
- * Report ID (4),
- * Logical Minimum (0),
- * Logical Maximum (255),
- * Usage (00h),
- * Report Size (8),
- * Report Count (3),
- * Feature (Variable),
- * End Collection
+ * See PF1209 description, device and HID report descriptors at
+ * http://sf.net/apps/mediawiki/digimend/?title=UC-Logic_Tablet_PF1209
*/
/* Size of the original descriptor of PF1209 tablet */
#define PF1209_RDESC_ORIG_SIZE 234
-/*
- * Fixed PF1209 report descriptor
- *
- * The descriptor is fixed similarly to WP5540U and WP8060U, plus the
- * feature report is removed, because its purpose is unknown and it is of no
- * use to the generic HID driver anyway for now.
- */
+/* Fixed PF1209 report descriptor */
static __u8 pf1209_rdesc_fixed[] = {
0x05, 0x0D, /* Usage Page (Digitizer), */
0x09, 0x02, /* Usage (Pen), */