[media] gspca_ov519: Fix support for the Terratec Terracam USB Pro
This is a camera with an ov518+ revision 0 bridge + ov7620ae sensor, which appearently needs different handling then the Trust spacecam 320, which has an ov518+ revision 2 + ov7620ae sensor. The Terracam USB Pro used to write this patch has kindly been provided by Dr. Tilmann Bubeck <t.bubeck@reinform.de>. Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Mauro Carvalho Chehab <m.chehab@samsung.com>
Diffstat (limited to 'drivers/media/usb')
-rw-r--r--drivers/media/usb/gspca/ov519.c32
1 files changed, 25 insertions, 7 deletions
diff --git a/drivers/media/usb/gspca/ov519.c b/drivers/media/usb/gspca/ov519.c
index a3958ee8681..8937d79fd17 100644
--- a/drivers/media/usb/gspca/ov519.c
+++ b/drivers/media/usb/gspca/ov519.c
@@ -75,6 +75,8 @@ struct sd {
struct v4l2_ctrl *brightness;
};
+ u8 revision;
+
u8 packet_nr;
char bridge;
@@ -3080,8 +3082,8 @@ static void ov518_configure(struct gspca_dev *gspca_dev)
};
/* First 5 bits of custom ID reg are a revision ID on OV518 */
- PDEBUG(D_PROBE, "Device revision %d",
- 0x1f & reg_r(sd, R51x_SYS_CUST_ID));
+ sd->revision = reg_r(sd, R51x_SYS_CUST_ID) & 0x1f;
+ PDEBUG(D_PROBE, "Device revision %d", sd->revision);
write_regvals(sd, init_518, ARRAY_SIZE(init_518));
@@ -3657,7 +3659,11 @@ static void ov518_mode_init_regs(struct sd *sd)
reg_w(sd, 0x2f, 0x80);
/******** Set the framerate ********/
- sd->clockdiv = 1;
+ if (sd->bridge == BRIDGE_OV518PLUS && sd->revision == 0 &&
+ sd->sensor == SEN_OV7620AE)
+ sd->clockdiv = 0;
+ else
+ sd->clockdiv = 1;
/* Mode independent, but framerate dependent, regs */
/* 0x51: Clock divider; Only works on some cams which use 2 crystals */
@@ -3668,12 +3674,24 @@ static void ov518_mode_init_regs(struct sd *sd)
if (sd->bridge == BRIDGE_OV518PLUS) {
switch (sd->sensor) {
case SEN_OV7620AE:
- if (sd->gspca_dev.width == 320) {
- reg_w(sd, 0x20, 0x00);
- reg_w(sd, 0x21, 0x19);
- } else {
+ /*
+ * HdG: 640x480 needs special handling on device
+ * revision 2, we check for device revison > 0 to
+ * avoid regressions, as we don't know the correct
+ * thing todo for revision 1.
+ *
+ * Also this likely means we don't need to
+ * differentiate between the OV7620 and OV7620AE,
+ * earlier testing hitting this same problem likely
+ * happened to be with revision < 2 cams using an
+ * OV7620 and revision 2 cams using an OV7620AE.
+ */
+ if (sd->revision > 0 && sd->gspca_dev.width == 640) {
reg_w(sd, 0x20, 0x60);
reg_w(sd, 0x21, 0x1f);
+ } else {
+ reg_w(sd, 0x20, 0x00);
+ reg_w(sd, 0x21, 0x19);
}
break;
case SEN_OV7620: