diff options
author | Christian Dietrich <qy03fugy@stud.informatik.uni-erlangen.de> | 2010-07-16 02:29:02 +0000 |
---|---|---|
committer | Josh Boyer <jwboyer@linux.vnet.ibm.com> | 2010-07-26 09:06:04 -0400 |
commit | c76986cca8379db619de4b6c6b7359125df0e341 (patch) | |
tree | caed6e53e9fecbbd3d75f96fa9723a5daf203a22 /drivers/mtd/maps | |
parent | cccd23428347251713b643d4bc5edb610308fd49 (diff) |
Remove REDWOOD_[456] config options and conditional code
The config options for REDWOOD_[456] were commented out in the powerpc
Kconfig. The ifdefs referencing this options therefore are dead and all
references to this can be removed (Also dependencies in other KConfig
files).
Signed-off-by: Christian Dietrich <qy03fugy@stud.informatik.uni-erlangen.de>
Signed-off-by: Christoph Egger <siccegge@cs.fau.de>
Acked-by: David S. Miller <davem@davemloft.net>
Acked-by: Benjamin Herrenschmidt <benh@kernel.crashing.org>
Signed-off-by: Josh Boyer <jwboyer@linux.vnet.ibm.com>
Diffstat (limited to 'drivers/mtd/maps')
-rw-r--r-- | drivers/mtd/maps/Kconfig | 2 | ||||
-rw-r--r-- | drivers/mtd/maps/redwood.c | 43 |
2 files changed, 1 insertions, 44 deletions
diff --git a/drivers/mtd/maps/Kconfig b/drivers/mtd/maps/Kconfig index f22bc9f05dd..6629d09f3b3 100644 --- a/drivers/mtd/maps/Kconfig +++ b/drivers/mtd/maps/Kconfig @@ -321,7 +321,7 @@ config MTD_CFI_FLAGADM config MTD_REDWOOD tristate "CFI Flash devices mapped on IBM Redwood" - depends on MTD_CFI && ( REDWOOD_4 || REDWOOD_5 || REDWOOD_6 ) + depends on MTD_CFI help This enables access routines for the flash chips on the IBM Redwood board. If you have one of these boards and would like to diff --git a/drivers/mtd/maps/redwood.c b/drivers/mtd/maps/redwood.c index 933c0b63b01..d2c9db00db0 100644 --- a/drivers/mtd/maps/redwood.c +++ b/drivers/mtd/maps/redwood.c @@ -22,8 +22,6 @@ #include <asm/io.h> -#if !defined (CONFIG_REDWOOD_6) - #define WINDOW_ADDR 0xffc00000 #define WINDOW_SIZE 0x00400000 @@ -69,47 +67,6 @@ static struct mtd_partition redwood_flash_partitions[] = { } }; -#else /* CONFIG_REDWOOD_6 */ -/* FIXME: the window is bigger - armin */ -#define WINDOW_ADDR 0xff800000 -#define WINDOW_SIZE 0x00800000 - -#define RW_PART0_OF 0 -#define RW_PART0_SZ 0x400000 /* 4 MiB data */ -#define RW_PART1_OF RW_PART0_OF + RW_PART0_SZ -#define RW_PART1_SZ 0x10000 /* 64K VPD */ -#define RW_PART2_OF RW_PART1_OF + RW_PART1_SZ -#define RW_PART2_SZ 0x400000 - (0x10000 + 0x20000) -#define RW_PART3_OF RW_PART2_OF + RW_PART2_SZ -#define RW_PART3_SZ 0x20000 - -static struct mtd_partition redwood_flash_partitions[] = { - { - .name = "Redwood filesystem", - .offset = RW_PART0_OF, - .size = RW_PART0_SZ - }, - { - .name = "Redwood OpenBIOS Vital Product Data", - .offset = RW_PART1_OF, - .size = RW_PART1_SZ, - .mask_flags = MTD_WRITEABLE /* force read-only */ - }, - { - .name = "Redwood kernel", - .offset = RW_PART2_OF, - .size = RW_PART2_SZ - }, - { - .name = "Redwood OpenBIOS", - .offset = RW_PART3_OF, - .size = RW_PART3_SZ, - .mask_flags = MTD_WRITEABLE /* force read-only */ - } -}; - -#endif /* CONFIG_REDWOOD_6 */ - struct map_info redwood_flash_map = { .name = "IBM Redwood", .size = WINDOW_SIZE, |