summaryrefslogtreecommitdiffstats
path: root/drivers/scsi
diff options
context:
space:
mode:
authorKashyap, Desai <kashyap.desai@lsi.com>2010-06-17 13:48:10 +0530
committerJames Bottomley <James.Bottomley@suse.de>2010-07-27 12:02:21 -0500
commitd417d1c3a3c3b4d89a285f82a4e7710372e40a24 (patch)
tree73529cc96a70beb5d82a0f0d1a0a2bcd2b407fb6 /drivers/scsi
parent3e2e833a547cbd0cb3fbe85a5f6ee71a93931fde (diff)
[SCSI] mpt2sas: Add additional check for responding volumes after Host Reset
ISSUE DESCRIPTION: This test case involves creating two RAID1 volumes, then simultaneiously issue host reset and pull all the drives associated to the 1st raid volume. The observed behavour is the physical drives are removed, however the volume remains. The expected behavour is the volume as well as physical drives should be removed from OS. FIX: Add support in the post host reset device scan logic for raid volumes where the driver will have an additional check for responding raid volume where the status should be either online, optimal, or degraded. So for voluemes that have a status of missing or failed, the driver will mark them for deletion. Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Diffstat (limited to 'drivers/scsi')
-rw-r--r--drivers/scsi/mpt2sas/mpt2sas_scsih.c14
1 files changed, 12 insertions, 2 deletions
diff --git a/drivers/scsi/mpt2sas/mpt2sas_scsih.c b/drivers/scsi/mpt2sas/mpt2sas_scsih.c
index b327d60fad1..228961b94a6 100644
--- a/drivers/scsi/mpt2sas/mpt2sas_scsih.c
+++ b/drivers/scsi/mpt2sas/mpt2sas_scsih.c
@@ -5952,6 +5952,7 @@ static void
_scsih_search_responding_raid_devices(struct MPT2SAS_ADAPTER *ioc)
{
Mpi2RaidVolPage1_t volume_pg1;
+ Mpi2RaidVolPage0_t volume_pg0;
Mpi2RaidPhysDiskPage0_t pd_pg0;
Mpi2ConfigReply_t mpi_reply;
u16 ioc_status;
@@ -5971,8 +5972,17 @@ _scsih_search_responding_raid_devices(struct MPT2SAS_ADAPTER *ioc)
if (ioc_status == MPI2_IOCSTATUS_CONFIG_INVALID_PAGE)
break;
handle = le16_to_cpu(volume_pg1.DevHandle);
- _scsih_mark_responding_raid_device(ioc,
- le64_to_cpu(volume_pg1.WWID), handle);
+
+ if (mpt2sas_config_get_raid_volume_pg0(ioc, &mpi_reply,
+ &volume_pg0, MPI2_RAID_VOLUME_PGAD_FORM_HANDLE, handle,
+ sizeof(Mpi2RaidVolPage0_t)))
+ continue;
+
+ if (volume_pg0.VolumeState == MPI2_RAID_VOL_STATE_OPTIMAL ||
+ volume_pg0.VolumeState == MPI2_RAID_VOL_STATE_ONLINE ||
+ volume_pg0.VolumeState == MPI2_RAID_VOL_STATE_DEGRADED)
+ _scsih_mark_responding_raid_device(ioc,
+ le64_to_cpu(volume_pg1.WWID), handle);
}
/* refresh the pd_handles */