diff options
author | Christoph Lameter <clameter@sgi.com> | 2005-07-12 16:03:00 -0700 |
---|---|---|
committer | Tony Luck <tony.luck@intel.com> | 2005-07-12 16:12:55 -0700 |
commit | 7c2a6c62c013a4ea57243536fc7f3987e4ba04bc (patch) | |
tree | 02e3e1d9888f81110ba85bef531e5c695f6064ce /include/asm-ia64/sn/pcibus_provider_defs.h | |
parent | 08357f82d4decc48bbfd39ae30d5fe0754f7f576 (diff) |
[IA64] Altix pcibus_to_node implementation
The Altix subarch does not provide node information via ACPI. Instead hooks
are used to fixup pci structures. This patch determines the nodes for Altix
PCI busses.
Remote Bridges:
---------------
Altix supports remote I/O nodes without memory or processors but with bridges.
The TIOCA type of bridge is an AGP bridge and the PROM provides information
about the closest node. That information will be returned by pcibus_to_node.
The TIOCP remote bridge type is a PCI bridge but the PROM does not provide a
closest node id. pcibus_to_node will return -1 for devices on those bridges
meaning that device control structures may be allocated on any node.
Safeguard:
----------
Should the fixups result in invalid node information for a pci controller then
a warning will be printed and pcibus_to_node will return -1.
This patch also fixes the "FIXME" in sn_dma_alloc_coherent. This means that
dma_alloc_coherent will now use alloc_pages_node to allocate memory local to
the node that the PCI device is connected to.
Signed-off-by: Christoph Lameter <clameter@sgi.com>
Signed-off-by: Tony Luck <tony.luck@intel.com>
Diffstat (limited to 'include/asm-ia64/sn/pcibus_provider_defs.h')
-rw-r--r-- | include/asm-ia64/sn/pcibus_provider_defs.h | 3 |
1 files changed, 2 insertions, 1 deletions
diff --git a/include/asm-ia64/sn/pcibus_provider_defs.h b/include/asm-ia64/sn/pcibus_provider_defs.h index 04e27d5b382..976f5eff053 100644 --- a/include/asm-ia64/sn/pcibus_provider_defs.h +++ b/include/asm-ia64/sn/pcibus_provider_defs.h @@ -37,6 +37,7 @@ struct pcibus_bussoft { struct xwidget_info *bs_xwidget_info; }; +struct pci_controller; /* * SN pci bus indirection */ @@ -45,7 +46,7 @@ struct sn_pcibus_provider { dma_addr_t (*dma_map)(struct pci_dev *, unsigned long, size_t); dma_addr_t (*dma_map_consistent)(struct pci_dev *, unsigned long, size_t); void (*dma_unmap)(struct pci_dev *, dma_addr_t, int); - void * (*bus_fixup)(struct pcibus_bussoft *); + void * (*bus_fixup)(struct pcibus_bussoft *, struct pci_controller *); }; extern struct sn_pcibus_provider *sn_pci_provider[]; |