summaryrefslogtreecommitdiffstats
path: root/include/linux/i2c
diff options
context:
space:
mode:
authorNeilBrown <neilb@suse.de>2012-05-09 07:40:40 +1000
committerAnton Vorontsov <cbouatmailru@gmail.com>2012-06-19 19:12:53 -0700
commit210d4bc8a3128e3e61ac3bf4657114f8e6450e2a (patch)
tree456c27828d2d3f4e76539736a0d53165932d7cd2 /include/linux/i2c
parent9c645d2f887bd92df487b2c5dcd44d5fc0e7c761 (diff)
twl4030_charger: Add backup-battery charging
This allows a voltage and current (bb_uvolts and bb_uamps) to be specified in the platform_data, and charging of the backup battery will be enabled with those specification. As it is not possible to monitor the backup battery at all there is no new device created to represent it. Signed-off-by: NeilBrown <neilb@suse.de> Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
Diffstat (limited to 'include/linux/i2c')
-rw-r--r--include/linux/i2c/twl.h2
1 files changed, 2 insertions, 0 deletions
diff --git a/include/linux/i2c/twl.h b/include/linux/i2c/twl.h
index 3993477103a..8eec4403b17 100644
--- a/include/linux/i2c/twl.h
+++ b/include/linux/i2c/twl.h
@@ -555,6 +555,8 @@ struct twl4030_clock_init_data {
struct twl4030_bci_platform_data {
int *battery_tmp_tbl;
unsigned int tblsize;
+ int bb_uvolt; /* voltage to charge backup battery */
+ int bb_uamp; /* current for backup battery charging */
};
/* TWL4030_GPIO_MAX (18) GPIOs, with interrupts */