authorAnderson Lizardo <anderson.lizardo@openbossa.org>2011-07-27 18:40:09 -0300
committerGustavo F. Padovan <gustavo@padovan.org>2011-09-27 18:16:27 -0300
commit0e8339151fa85cb9b088abfb13e2dd5214a25429 (patch)
tree4d8216a45e19e025c1f143b5f435ba6446f6fc8d /net/bluetooth/hidp
parent84084a3197a9fdec10fa542c0df11928a784e7fc (diff)
Bluetooth: use recommended LE connection parameters
The new connection parameters now match the recommended values for Proximity and Health Thermometer profiles. The previous values were ramdomly chosen, and are either too low or too high for most cases. New values: Scan Interval: 60 ms Scan Window: 30 ms Minimum Connection Interval: 50 ms Maximum Connection Interval: 70 ms Supervision Timeout: 420 ms See "Table 5.2: Recommended Scan Interval and Scan Window Values" and "Table 5.3: Recommended Connection Interval Values" for both profiles for details. Note that the "fast connection" parameters were chosen, because we do not support yet dynamically changing these parameters from initiator side. Additionally, the Proximity profile recommends (section "4.4 Alert on Link Loss"): "It is recommended that the Link Supervision Timeout (LSTO) is set to 6x the connection interval." Minimum_CE_Length and Maximum_CE_Length were also changed from 0x0001 to 0x0000 because they are informational and optional, and old value was not reflecting reality. Signed-off-by: Anderson Lizardo <anderson.lizardo@openbossa.org> Signed-off-by: Gustavo F. Padovan <padovan@profusion.mobi>