diff options
author | Florent Fourcot <florent.fourcot@enst-bretagne.fr> | 2013-11-07 17:53:13 +0100 |
---|---|---|
committer | David S. Miller <davem@davemloft.net> | 2013-11-08 13:43:52 -0500 |
commit | 53b47106c0c2b1f42237d255ae272f0fcc3ec413 (patch) | |
tree | c44661223011d6119f9d9d3a0b05b9a594f7eccb /net/ipv6 | |
parent | 3fdfa5ff50aee5b524fb22b6e0e511b73752a257 (diff) |
ipv6: increase maximum lifetime of flow labels
If the last RFC 6437 does not give any constraints
for lifetime of flow labels, the previous RFC 3697
spoke of a minimum of 120 seconds between
reattribution of a flow label.
The maximum linger is currently set to 60 seconds
and does not allow this configuration without
CAP_NET_ADMIN right.
This patch increase the maximum linger to 150
seconds, allowing more flexibility to standard
users.
Signed-off-by: Florent Fourcot <florent.fourcot@enst-bretagne.fr>
Acked-by: Hannes Frederic Sowa <hannes@stressinduktion.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'net/ipv6')
-rw-r--r-- | net/ipv6/ip6_flowlabel.c | 2 |
1 files changed, 1 insertions, 1 deletions
diff --git a/net/ipv6/ip6_flowlabel.c b/net/ipv6/ip6_flowlabel.c index 4a06ed01d0c..5f10b0d0bca 100644 --- a/net/ipv6/ip6_flowlabel.c +++ b/net/ipv6/ip6_flowlabel.c @@ -41,7 +41,7 @@ #define FL_MIN_LINGER 6 /* Minimal linger. It is set to 6sec specified in old IPv6 RFC. Well, it was reasonable value. */ -#define FL_MAX_LINGER 60 /* Maximal linger timeout */ +#define FL_MAX_LINGER 150 /* Maximal linger timeout */ /* FL hash table */ |