diff options
author | Martin Peres <martin.peres@labri.fr> | 2012-12-20 01:32:09 +0100 |
---|---|---|
committer | Ben Skeggs <bskeggs@redhat.com> | 2013-02-20 16:00:33 +1000 |
commit | a624bafbf11c098a859dba4118a33605bfd25788 (patch) | |
tree | 1b360eaa93d2668d633ea0bae186e674c82ebdf0 /scripts | |
parent | 93260d3c026b539931d909a4d68490c32b6d73ce (diff) |
drm/nouveau/fan: handle the cases where we are outside of the linear zone
This fixes a bug where, when temperature is outside of the linear range, fan
pwm would be outside of the allowed range ([0, 100]) and could get negative in
some cases.
It seems like a regression that happened when we re-worked the fan management
logic before merging.
Tested-by: Ozan Çağlayan <ozancag@gmail.com>
Signed-off-by: Martin Peres <martin.peres@labri.fr>
Signed-off-by: Ben Skeggs <bskeggs@redhat.com>
Diffstat (limited to 'scripts')
0 files changed, 0 insertions, 0 deletions