summaryrefslogtreecommitdiffstats
path: root/sound/soc/tegra
diff options
context:
space:
mode:
authorStephen Warren <swarren@nvidia.com>2013-08-14 14:24:16 -0600
committerMark Brown <broonie@linaro.org>2013-08-15 11:07:53 +0100
commitc90c0d7a96e634a73ef1580f1d20993606545647 (patch)
treede70856609478555ff8ff19e6076d23ae22080dc /sound/soc/tegra
parentd4e4ab86bcba5a72779c43dc1459f71fea3d89c8 (diff)
ASoC: tegra: fix Tegra30 I2S capture parameter setup
The Tegra30 I2S driver was writing the AHUB interface parameters to the playback path register rather than the capture path register. This caused the capture parameters not to be configured at all, so if capturing using non-HW-default parameters (e.g. 16-bit stereo rather than 8-bit mono) the audio would be corrupted. With this fixed, audio capture from an analog microphone works correctly on the Cardhu board. Cc: stable@vger.kernel.org Signed-off-by: Stephen Warren <swarren@nvidia.com> Signed-off-by: Mark Brown <broonie@linaro.org>
Diffstat (limited to 'sound/soc/tegra')
-rw-r--r--sound/soc/tegra/tegra30_i2s.c2
1 files changed, 1 insertions, 1 deletions
diff --git a/sound/soc/tegra/tegra30_i2s.c b/sound/soc/tegra/tegra30_i2s.c
index d04146cad61..47565fd0450 100644
--- a/sound/soc/tegra/tegra30_i2s.c
+++ b/sound/soc/tegra/tegra30_i2s.c
@@ -228,7 +228,7 @@ static int tegra30_i2s_hw_params(struct snd_pcm_substream *substream,
reg = TEGRA30_I2S_CIF_RX_CTRL;
} else {
val |= TEGRA30_AUDIOCIF_CTRL_DIRECTION_TX;
- reg = TEGRA30_I2S_CIF_RX_CTRL;
+ reg = TEGRA30_I2S_CIF_TX_CTRL;
}
regmap_write(i2s->regmap, reg, val);