summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
-rw-r--r--drivers/acpi/processor_thermal.c30
1 files changed, 16 insertions, 14 deletions
diff --git a/drivers/acpi/processor_thermal.c b/drivers/acpi/processor_thermal.c
index 9cb43f52f7b..649ae99b921 100644
--- a/drivers/acpi/processor_thermal.c
+++ b/drivers/acpi/processor_thermal.c
@@ -97,7 +97,7 @@ static int acpi_processor_apply_limit(struct acpi_processor *pr)
#define CPUFREQ_THERMAL_MIN_STEP 0
#define CPUFREQ_THERMAL_MAX_STEP 3
-static unsigned int cpufreq_thermal_reduction_pctg[NR_CPUS];
+static DEFINE_PER_CPU(unsigned int, cpufreq_thermal_reduction_pctg);
static unsigned int acpi_thermal_cpufreq_is_init = 0;
static int cpu_has_cpufreq(unsigned int cpu)
@@ -113,9 +113,9 @@ static int acpi_thermal_cpufreq_increase(unsigned int cpu)
if (!cpu_has_cpufreq(cpu))
return -ENODEV;
- if (cpufreq_thermal_reduction_pctg[cpu] <
+ if (per_cpu(cpufreq_thermal_reduction_pctg, cpu) <
CPUFREQ_THERMAL_MAX_STEP) {
- cpufreq_thermal_reduction_pctg[cpu]++;
+ per_cpu(cpufreq_thermal_reduction_pctg, cpu)++;
cpufreq_update_policy(cpu);
return 0;
}
@@ -128,14 +128,14 @@ static int acpi_thermal_cpufreq_decrease(unsigned int cpu)
if (!cpu_has_cpufreq(cpu))
return -ENODEV;
- if (cpufreq_thermal_reduction_pctg[cpu] >
+ if (per_cpu(cpufreq_thermal_reduction_pctg, cpu) >
(CPUFREQ_THERMAL_MIN_STEP + 1))
- cpufreq_thermal_reduction_pctg[cpu]--;
+ per_cpu(cpufreq_thermal_reduction_pctg, cpu)--;
else
- cpufreq_thermal_reduction_pctg[cpu] = 0;
+ per_cpu(cpufreq_thermal_reduction_pctg, cpu) = 0;
cpufreq_update_policy(cpu);
/* We reached max freq again and can leave passive mode */
- return !cpufreq_thermal_reduction_pctg[cpu];
+ return !per_cpu(cpufreq_thermal_reduction_pctg, cpu);
}
static int acpi_thermal_cpufreq_notifier(struct notifier_block *nb,
@@ -147,9 +147,10 @@ static int acpi_thermal_cpufreq_notifier(struct notifier_block *nb,
if (event != CPUFREQ_ADJUST)
goto out;
- max_freq =
- (policy->cpuinfo.max_freq *
- (100 - cpufreq_thermal_reduction_pctg[policy->cpu] * 20)) / 100;
+ max_freq = (
+ policy->cpuinfo.max_freq *
+ (100 - per_cpu(cpufreq_thermal_reduction_pctg, policy->cpu) * 20)
+ ) / 100;
cpufreq_verify_within_limits(policy, 0, max_freq);
@@ -174,7 +175,7 @@ static int cpufreq_get_cur_state(unsigned int cpu)
if (!cpu_has_cpufreq(cpu))
return 0;
- return cpufreq_thermal_reduction_pctg[cpu];
+ return per_cpu(cpufreq_thermal_reduction_pctg, cpu);
}
static int cpufreq_set_cur_state(unsigned int cpu, int state)
@@ -182,7 +183,7 @@ static int cpufreq_set_cur_state(unsigned int cpu, int state)
if (!cpu_has_cpufreq(cpu))
return 0;
- cpufreq_thermal_reduction_pctg[cpu] = state;
+ per_cpu(cpufreq_thermal_reduction_pctg, cpu) = state;
cpufreq_update_policy(cpu);
return 0;
}
@@ -191,8 +192,9 @@ void acpi_thermal_cpufreq_init(void)
{
int i;
- for (i = 0; i < NR_CPUS; i++)
- cpufreq_thermal_reduction_pctg[i] = 0;
+ for (i = 0; i < nr_cpu_ids; i++)
+ if (cpu_present(i))
+ per_cpu(cpufreq_thermal_reduction_pctg, i) = 0;
i = cpufreq_register_notifier(&acpi_thermal_cpufreq_notifier_block,
CPUFREQ_POLICY_NOTIFIER);