summaryrefslogtreecommitdiffstats
path: root/Documentation/cgroups/blkio-controller.txt
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/cgroups/blkio-controller.txt')
-rw-r--r--Documentation/cgroups/blkio-controller.txt30
1 files changed, 1 insertions, 29 deletions
diff --git a/Documentation/cgroups/blkio-controller.txt b/Documentation/cgroups/blkio-controller.txt
index 4ed7b5ceeed..465351d4cf8 100644
--- a/Documentation/cgroups/blkio-controller.txt
+++ b/Documentation/cgroups/blkio-controller.txt
@@ -140,7 +140,7 @@ Proportional weight policy files
- Specifies per cgroup weight. This is default weight of the group
on all the devices until and unless overridden by per device rule.
(See blkio.weight_device).
- Currently allowed range of weights is from 100 to 1000.
+ Currently allowed range of weights is from 10 to 1000.
- blkio.weight_device
- One can specify per cgroup per device rules using this interface.
@@ -343,34 +343,6 @@ Common files among various policies
CFQ sysfs tunable
=================
-/sys/block/<disk>/queue/iosched/group_isolation
------------------------------------------------
-
-If group_isolation=1, it provides stronger isolation between groups at the
-expense of throughput. By default group_isolation is 0. In general that
-means that if group_isolation=0, expect fairness for sequential workload
-only. Set group_isolation=1 to see fairness for random IO workload also.
-
-Generally CFQ will put random seeky workload in sync-noidle category. CFQ
-will disable idling on these queues and it does a collective idling on group
-of such queues. Generally these are slow moving queues and if there is a
-sync-noidle service tree in each group, that group gets exclusive access to
-disk for certain period. That means it will bring the throughput down if
-group does not have enough IO to drive deeper queue depths and utilize disk
-capacity to the fullest in the slice allocated to it. But the flip side is
-that even a random reader should get better latencies and overall throughput
-if there are lots of sequential readers/sync-idle workload running in the
-system.
-
-If group_isolation=0, then CFQ automatically moves all the random seeky queues
-in the root group. That means there will be no service differentiation for
-that kind of workload. This leads to better throughput as we do collective
-idling on root sync-noidle tree.
-
-By default one should run with group_isolation=0. If that is not sufficient
-and one wants stronger isolation between groups, then set group_isolation=1
-but this will come at cost of reduced throughput.
-
/sys/block/<disk>/queue/iosched/slice_idle
------------------------------------------
On a faster hardware CFQ can be slow, especially with sequential workload.