summaryrefslogtreecommitdiffstats
path: root/Documentation/hwmon
diff options
context:
space:
mode:
Diffstat (limited to 'Documentation/hwmon')
-rw-r--r--Documentation/hwmon/tmp1029
1 files changed, 4 insertions, 5 deletions
diff --git a/Documentation/hwmon/tmp102 b/Documentation/hwmon/tmp102
index 239dded8539..8454a776312 100644
--- a/Documentation/hwmon/tmp102
+++ b/Documentation/hwmon/tmp102
@@ -4,7 +4,7 @@ Kernel driver tmp102
Supported chips:
* Texas Instruments TMP102
Prefix: 'tmp102'
- Addresses scanned: I2C 0x48 0x49 0x4a 0x4b
+ Addresses scanned: none
Datasheet: http://focus.ti.com/docs/prod/folders/print/tmp102.html
Author:
@@ -15,13 +15,12 @@ Description
The Texas Instruments TMP102 implements one temperature sensor. Limits can be
set through the Overtemperature Shutdown register and Hysteresis register. The
-sensor is accurate to 0.5 degrees over the range of -25 to +85 C, and to 1.0
-degrees from -40 to +125 C. Resolution of the sensor is 0.0625 degree. The
+sensor is accurate to 0.5 degree over the range of -25 to +85 C, and to 1.0
+degree from -40 to +125 C. Resolution of the sensor is 0.0625 degree. The
operating temperature has a minimum of -55 C and a maximum of +150 C.
The TMP102 has a programmable update rate that can select between 8, 4, 1, and
0.5 Hz. (Currently the driver only supports the default of 4 Hz).
The driver provides the common sysfs-interface for temperatures (see
-/Documentation/hwmon/sysfs-interface under Temperatures).
-
+Documentation/hwmon/sysfs-interface under Temperatures).