summaryrefslogtreecommitdiffstats
path: root/drivers/cpufreq/cpufreq-cpu0.c
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/cpufreq/cpufreq-cpu0.c')
-rw-r--r--drivers/cpufreq/cpufreq-cpu0.c26
1 files changed, 19 insertions, 7 deletions
diff --git a/drivers/cpufreq/cpufreq-cpu0.c b/drivers/cpufreq/cpufreq-cpu0.c
index d4585ce2346..0c12ffc0ebc 100644
--- a/drivers/cpufreq/cpufreq-cpu0.c
+++ b/drivers/cpufreq/cpufreq-cpu0.c
@@ -13,7 +13,9 @@
#include <linux/clk.h>
#include <linux/cpu.h>
+#include <linux/cpu_cooling.h>
#include <linux/cpufreq.h>
+#include <linux/cpumask.h>
#include <linux/err.h>
#include <linux/module.h>
#include <linux/of.h>
@@ -21,6 +23,7 @@
#include <linux/platform_device.h>
#include <linux/regulator/consumer.h>
#include <linux/slab.h>
+#include <linux/thermal.h>
static unsigned int transition_latency;
static unsigned int voltage_tolerance; /* in percentage */
@@ -29,11 +32,7 @@ static struct device *cpu_dev;
static struct clk *cpu_clk;
static struct regulator *cpu_reg;
static struct cpufreq_frequency_table *freq_table;
-
-static unsigned int cpu0_get_speed(unsigned int cpu)
-{
- return clk_get_rate(cpu_clk) / 1000;
-}
+static struct thermal_cooling_device *cdev;
static int cpu0_set_target(struct cpufreq_policy *policy, unsigned int index)
{
@@ -44,7 +43,7 @@ static int cpu0_set_target(struct cpufreq_policy *policy, unsigned int index)
int ret;
freq_Hz = clk_round_rate(cpu_clk, freq_table[index].frequency * 1000);
- if (freq_Hz < 0)
+ if (freq_Hz <= 0)
freq_Hz = freq_table[index].frequency * 1000;
freq_exact = freq_Hz;
@@ -100,6 +99,7 @@ static int cpu0_set_target(struct cpufreq_policy *policy, unsigned int index)
static int cpu0_cpufreq_init(struct cpufreq_policy *policy)
{
+ policy->clk = cpu_clk;
return cpufreq_generic_init(policy, freq_table, transition_latency);
}
@@ -107,7 +107,7 @@ static struct cpufreq_driver cpu0_cpufreq_driver = {
.flags = CPUFREQ_STICKY,
.verify = cpufreq_generic_frequency_table_verify,
.target_index = cpu0_set_target,
- .get = cpu0_get_speed,
+ .get = cpufreq_generic_get,
.init = cpu0_cpufreq_init,
.exit = cpufreq_generic_exit,
.name = "generic_cpu0",
@@ -201,6 +201,17 @@ static int cpu0_cpufreq_probe(struct platform_device *pdev)
goto out_free_table;
}
+ /*
+ * For now, just loading the cooling device;
+ * thermal DT code takes care of matching them.
+ */
+ if (of_find_property(np, "#cooling-cells", NULL)) {
+ cdev = of_cpufreq_cooling_register(np, cpu_present_mask);
+ if (IS_ERR(cdev))
+ pr_err("running cpufreq without cooling device: %ld\n",
+ PTR_ERR(cdev));
+ }
+
of_node_put(np);
return 0;
@@ -213,6 +224,7 @@ out_put_node:
static int cpu0_cpufreq_remove(struct platform_device *pdev)
{
+ cpufreq_cooling_unregister(cdev);
cpufreq_unregister_driver(&cpu0_cpufreq_driver);
dev_pm_opp_free_cpufreq_table(cpu_dev, &freq_table);