summaryrefslogtreecommitdiffstats
path: root/drivers/thermal/kirkwood_thermal.c
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/thermal/kirkwood_thermal.c')
-rw-r--r--drivers/thermal/kirkwood_thermal.c12
1 files changed, 6 insertions, 6 deletions
diff --git a/drivers/thermal/kirkwood_thermal.c b/drivers/thermal/kirkwood_thermal.c
index e5500edb528..dfeceaffbc0 100644
--- a/drivers/thermal/kirkwood_thermal.c
+++ b/drivers/thermal/kirkwood_thermal.c
@@ -41,21 +41,21 @@ static int kirkwood_get_temp(struct thermal_zone_device *thermal,
reg = readl_relaxed(priv->sensor);
/* Valid check */
- if (!(reg >> KIRKWOOD_THERMAL_VALID_OFFSET) &
- KIRKWOOD_THERMAL_VALID_MASK) {
+ if (!((reg >> KIRKWOOD_THERMAL_VALID_OFFSET) &
+ KIRKWOOD_THERMAL_VALID_MASK)) {
dev_err(&thermal->device,
"Temperature sensor reading not valid\n");
return -EIO;
}
/*
- * Calculate temperature. See Section 8.10.1 of the 88AP510,
- * datasheet, which has the same sensor.
- * Documentation/arm/Marvell/README
+ * Calculate temperature. According to Marvell internal
+ * documentation the formula for this is:
+ * Celsius = (322-reg)/1.3625
*/
reg = (reg >> KIRKWOOD_THERMAL_TEMP_OFFSET) &
KIRKWOOD_THERMAL_TEMP_MASK;
- *temp = ((2281638UL - (7298*reg)) / 10);
+ *temp = ((3220000000UL - (10000000UL * reg)) / 13625);
return 0;
}