summaryrefslogtreecommitdiffstats
path: root/fs/cifs/inode.c
diff options
context:
space:
mode:
Diffstat (limited to 'fs/cifs/inode.c')
-rw-r--r--fs/cifs/inode.c104
1 files changed, 64 insertions, 40 deletions
diff --git a/fs/cifs/inode.c b/fs/cifs/inode.c
index bcf7b518466..4690a360c85 100644
--- a/fs/cifs/inode.c
+++ b/fs/cifs/inode.c
@@ -199,6 +199,49 @@ static void fill_fake_finddataunix(FILE_UNIX_BASIC_INFO *pfnd_dat,
pfnd_dat->Gid = cpu_to_le64(pinode->i_gid);
}
+/**
+ * cifs_new inode - create new inode, initialize, and hash it
+ * @sb - pointer to superblock
+ * @inum - if valid pointer and serverino is enabled, replace i_ino with val
+ *
+ * Create a new inode, initialize it for CIFS and hash it. Returns the new
+ * inode or NULL if one couldn't be allocated.
+ *
+ * If the share isn't mounted with "serverino" or inum is a NULL pointer then
+ * we'll just use the inode number assigned by new_inode(). Note that this can
+ * mean i_ino collisions since the i_ino assigned by new_inode is not
+ * guaranteed to be unique.
+ */
+struct inode *
+cifs_new_inode(struct super_block *sb, __u64 *inum)
+{
+ struct inode *inode;
+
+ inode = new_inode(sb);
+ if (inode == NULL)
+ return NULL;
+
+ /*
+ * BB: Is i_ino == 0 legal? Here, we assume that it is. If it isn't we
+ * stop passing inum as ptr. Are there sanity checks we can use to
+ * ensure that the server is really filling in that field? Also,
+ * if serverino is disabled, perhaps we should be using iunique()?
+ */
+ if (inum && (CIFS_SB(sb)->mnt_cifs_flags & CIFS_MOUNT_SERVER_INUM))
+ inode->i_ino = (unsigned long) *inum;
+
+ /*
+ * must set this here instead of cifs_alloc_inode since VFS will
+ * clobber i_flags
+ */
+ if (sb->s_flags & MS_NOATIME)
+ inode->i_flags |= S_NOATIME | S_NOCMTIME;
+
+ insert_inode_hash(inode);
+
+ return inode;
+}
+
int cifs_get_inode_info_unix(struct inode **pinode,
const unsigned char *full_path, struct super_block *sb, int xid)
{
@@ -233,22 +276,11 @@ int cifs_get_inode_info_unix(struct inode **pinode,
/* get new inode */
if (*pinode == NULL) {
- *pinode = new_inode(sb);
+ *pinode = cifs_new_inode(sb, &find_data.UniqueId);
if (*pinode == NULL) {
rc = -ENOMEM;
goto cgiiu_exit;
}
- /* Is an i_ino of zero legal? */
- /* note ino incremented to unique num in new_inode */
- /* Are there sanity checks we can use to ensure that
- the server is really filling in that field? */
- if (cifs_sb->mnt_cifs_flags & CIFS_MOUNT_SERVER_INUM)
- (*pinode)->i_ino = (unsigned long)find_data.UniqueId;
-
- if (sb->s_flags & MS_NOATIME)
- (*pinode)->i_flags |= S_NOATIME | S_NOCMTIME;
-
- insert_inode_hash(*pinode);
}
inode = *pinode;
@@ -465,11 +497,9 @@ int cifs_get_inode_info(struct inode **pinode,
/* get new inode */
if (*pinode == NULL) {
- *pinode = new_inode(sb);
- if (*pinode == NULL) {
- rc = -ENOMEM;
- goto cgii_exit;
- }
+ __u64 inode_num;
+ __u64 *pinum = &inode_num;
+
/* Is an i_ino of zero legal? Can we use that to check
if the server supports returning inode numbers? Are
there other sanity checks we can use to ensure that
@@ -486,22 +516,26 @@ int cifs_get_inode_info(struct inode **pinode,
if (cifs_sb->mnt_cifs_flags & CIFS_MOUNT_SERVER_INUM) {
int rc1 = 0;
- __u64 inode_num;
rc1 = CIFSGetSrvInodeNumber(xid, pTcon,
- full_path, &inode_num,
+ full_path, pinum,
cifs_sb->local_nls,
cifs_sb->mnt_cifs_flags &
CIFS_MOUNT_MAP_SPECIAL_CHR);
if (rc1) {
cFYI(1, ("GetSrvInodeNum rc %d", rc1));
+ pinum = NULL;
/* BB EOPNOSUPP disable SERVER_INUM? */
- } else /* do we need cast or hash to ino? */
- (*pinode)->i_ino = inode_num;
- } /* else ino incremented to unique num in new_inode*/
- if (sb->s_flags & MS_NOATIME)
- (*pinode)->i_flags |= S_NOATIME | S_NOCMTIME;
- insert_inode_hash(*pinode);
+ }
+ } else {
+ pinum = NULL;
+ }
+
+ *pinode = cifs_new_inode(sb, pinum);
+ if (*pinode == NULL) {
+ rc = -ENOMEM;
+ goto cgii_exit;
+ }
}
inode = *pinode;
cifsInfo = CIFS_I(inode);
@@ -621,7 +655,7 @@ static const struct inode_operations cifs_ipc_inode_ops = {
.lookup = cifs_lookup,
};
-static char *build_path_to_root(struct cifs_sb_info *cifs_sb)
+char *cifs_build_path_to_root(struct cifs_sb_info *cifs_sb)
{
int pplen = cifs_sb->prepathlen;
int dfsplen;
@@ -678,7 +712,7 @@ struct inode *cifs_iget(struct super_block *sb, unsigned long ino)
return inode;
cifs_sb = CIFS_SB(inode->i_sb);
- full_path = build_path_to_root(cifs_sb);
+ full_path = cifs_build_path_to_root(cifs_sb);
if (full_path == NULL)
return ERR_PTR(-ENOMEM);
@@ -1017,7 +1051,7 @@ out_reval:
return rc;
}
-static void posix_fill_in_inode(struct inode *tmp_inode,
+void posix_fill_in_inode(struct inode *tmp_inode,
FILE_UNIX_BASIC_INFO *pData, int isNewInode)
{
struct cifsInodeInfo *cifsInfo = CIFS_I(tmp_inode);
@@ -1114,24 +1148,14 @@ int cifs_mkdir(struct inode *inode, struct dentry *direntry, int mode)
else
direntry->d_op = &cifs_dentry_ops;
- newinode = new_inode(inode->i_sb);
+ newinode = cifs_new_inode(inode->i_sb,
+ &pInfo->UniqueId);
if (newinode == NULL) {
kfree(pInfo);
goto mkdir_get_info;
}
- /* Is an i_ino of zero legal? */
- /* Are there sanity checks we can use to ensure that
- the server is really filling in that field? */
- if (cifs_sb->mnt_cifs_flags & CIFS_MOUNT_SERVER_INUM) {
- newinode->i_ino =
- (unsigned long)pInfo->UniqueId;
- } /* note ino incremented to unique num in new_inode */
- if (inode->i_sb->s_flags & MS_NOATIME)
- newinode->i_flags |= S_NOATIME | S_NOCMTIME;
newinode->i_nlink = 2;
-
- insert_inode_hash(newinode);
d_instantiate(direntry, newinode);
/* we already checked in POSIXCreate whether