Age | Commit message (Collapse) | Author |
|
Just set vref_mv in your platform config to use external vref. Otherwise
the internal one is used.
Signed-off-by: Alexander Stein <alexander.stein@systec-electronic.com>
Signed-off-by: Dmitry Torokhov <dtor@mail.ru>
|
|
Tested-by: Anatolij Gustschin <agust@denx.de>
Signed-off-by: Dmitry Torokhov <dtor@mail.ru>
|
|
On some platforms, for example with GPIO interrupts on mpc5121,
it is not possible to configure falling edge interrupts.
Specifying irq trigger type in platform data structure
allows using ads7846 driver on such platforms.
Signed-off-by: Anatolij Gustschin <agust@denx.de>
Signed-off-by: Dmitry Torokhov <dtor@mail.ru>
|
|
Add wakeup support to the ads7846 driver. Platforms can enable wakeup
capability by setting the wakeup flag in ads7846_platform_data. With this
patch the ads7846 driver can be used to wake the system from suspend.
Signed-off-by: Ranjith Lohithakshan <ranjithl@ti.com>
Signed-off-by: Dmitry Torokhov <dtor@mail.ru>
|
|
The AD7873 is almost identical to the ADS7846; the only difference is
related to the Power Management bits PD0 and PD1. This results in a
slightly different PENIRQ enable behavior. For the AD7873, VREF should
be turned off during differential measurements.
So, add the AD7873/43 to the list of driver supported devices, and prevent
VREF usage during differential/ratiometric conversion modes.
Signed-off-by: Michael Hennerich <michael.hennerich@analog.com>
Signed-off-by: Mike Frysinger <vapier@gentoo.org>
Signed-off-by: Dmitry Torokhov <dtor@mail.ru>
|
|
Signed-off-by: Michael Roth <mroth@nessie.de>
Signed-off-by: Dmitry Torokhov <dtor@mail.ru>
|
|
Noises can be introduced when LCD signals are being driven, some platforms
provide a signal to assist the synchronization of this sampling procedure.
Signed-off-by: Eric Miao <eric.miao@marvell.com>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Dmitry Torokhov <dtor@mail.ru>
|
|
The GPIO connected to ADS7846 nPENIRQ signal is usually used to get
the pendown state as well. Introduce a .gpio_pendown, and use this
to decide the pendown state if .get_pendown_state is NULL.
Signed-off-by: Eric Miao <eric.miao@marvell.com>
Signed-off-by: Dmitry Torokhov <dtor@mail.ru>
|
|
This updates the ads7846 driver to handle external vREF (required
on boards using ads7843 chips) without module parameters, and also
removes a needless variable with its associated bogus gcc warning.
Signed-off-by: David Brownell <dbrownell@users.sourceforge.net>
Signed-off-by: Dmitry Torokhov <dtor@mail.ru>
|
|
Pendown status from the PENIRQ pin is currently read only at the beginning
of a sample set. If the pen is lifted just after sampling has began then
sampled values become wrong.
This patch adds an optional platform penirq_recheck_delay attribute. If
non-zero, samples are only reported to the input subsystem if PENIRQ is
still active that long after the samples taken.
Signed-off-by: Semih Hazar <semih.hazar@indefia.com>
Signed-off-by: David Brownell <dbrownell@users.sourceforge.net>
Signed-off-by: Dmitry Torokhov <dtor@mail.ru>
|
|
The ads7846 driver has support for filtering, but when the chip gets
deselected between samples this causes noise. This patch adds support
for an optional settling delay time, so that two consecutive samples
will be taken with the specified delay time apart. This ensures that
the chip won't be deselected, so the noise won't appear.
Filtering can still be done, but will have less work to do since each
time a new sample is taken the same delay applies.
Signed-off-by: Semih Hazar <semih.hazar@indefia.com>
Signed-off-by: David Brownell <dbrownell@users.sourceforge.net>
Signed-off-by: Dmitry Torokhov <dtor@mail.ru>
|
|
On some LCDs leaving the Vref on provides much better readings.
Signed-off-by: Jarkko Oikarinen <jarkko.oikarinen@nokia.com>
Signed-off-by: Imre Deak <imre.deak@solidboot.com>
Signed-off-by: Juha Yrjola <juha.yrjola@solidboot.com>
Signed-off-by: David Brownell <dbrownell@users.sourceforge.net>
Signed-off-by: Dmitry Torokhov <dtor@mail.ru>
|
|
Some LCDs like the LS041Y3 require a customized filtering
logic for reliable readings, so make the filtering function
replacable through platform specific hooks.
Signed-off-by: Imre Deak <imre.deak@solidboot.com>
Signed-off-by: Juha Yrjola <juha.yrjola@solidboot.com>
Signed-off-by: David Brownell <dbrownell@users.sourceforge.net>
Signed-off-by: Dmitry Torokhov <dtor@mail.ru>
|
|
Providing more accurate coordinates for thumb press requires additional
steps in the filtering logic:
- Ignore samples found invalid by the debouncing logic, or the ones that
have out of bound pressure value.
- Add a parameter to repeat debouncing, so that more then two consecutive
good readings are required for a valid sample.
Signed-off-by: Imre Deak <imre.deak@nokia.com>
Acked-by: Juha Yrjola <juha.yrjola@nokia.com>
Signed-off-by: Dmitry Torokhov <dtor@mail.ru>
|
|
The pen down IRQ will toggle during each X,Y,Z measurement cycle.
Even though the IRQ is disabled it will be latched and delivered
when after enable_irq. Thus in the IRQ handler we must avoid
starting a new measurement cycle when such an "unwanted" IRQ happens.
Add a get_pendown_state platform function, which will probably
determine this by reading the current GPIO level of the pen IRQ pin.
Move the IRQ reenabling from the SPI RX function to the timer. After
the last power down message the pen IRQ pin is still active for a
while and get_pendown_state would report incorrectly a pen down state.
When suspending we should check the ts->pending flag instead of
ts->pendown, since the timer can be pending regardless of ts->pendown.
Also if ts->pending is set we can be sure that the timer is running,
so no need to rearm it. Similarly if ts->pending is not set we can
be sure that the IRQ is enabled (and the timer is not).
Signed-off-by: Imre Deak <imre.deak@nokia.com>
Signed-off-by: David Brownell <dbrownell@users.sourceforge.net>
Signed-off-by: Dmitry Torokhov <dtor@mail.ru>
|
|
Some touchscreens seem to oscillate heavily for a while after touching
the screen. Implement support for sampling the screen until we get two
consecutive values that are close enough.
Signed-off-by: Imre Deak <imre.deak@nokia.com>
Signed-off-by: Juha Yrjola <juha.yrjola@nokia.com>
Signed-off-by: David Brownell <dbrownell@users.sourceforge.net>
Signed-off-by: Dmitry Torokhov <dtor@mail.ru>
|
|
This updates the ads7864 driver to use the new "spi_driver" struct, and
includes some minor unrelated cleanup.
Signed-off-by: David Brownell <dbrownell@users.sourceforge.net>
Signed-off-by: Andrew Morton <akpm@osdl.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
|
|
This is a driver for the ADS7846 touchscreen sensor, derived from
the corgi_ts and omap_ts drivers. Key differences from those two:
- Uses the new SPI framework (minimalist version)
- <linux/spi/ads7846.h> abstracts board-specific touchscreen info
- Sysfs attributes for the temperature and voltage sensors
- Uses fewer ARM-specific IRQ primitives
The temperature and voltage sensors show up in sysfs like this:
$ pwd
/sys/devices/platform/omap-uwire/spi2.0
$ ls
bus@ input:event0@ power/ temp1 vbatt
driver@ modalias temp0 vaux
$ cat modalias
ads7846
$ cat temp0
991
$ cat temp1
1177
$
So far only basic testing has been done. There's a fair amount of hardware
that uses this sensor, and which also runs Linux, which should eventually
be able to use this driver.
One portability note may be of special interest. It turns out that not all
SPI controllers are happy issuing requests that do things like "write 8 bit
command, read 12 bit response". Most of them seem happy to handle various
word sizes, so the issue isn't "12 bit response" but rather "different rx
and tx write sizes", despite that being a common MicroWire convention. So
this version of the driver no longer reads 12 bit native-endian words; it
reads 16-bit big-endian responses, then byteswaps them and shifts the
results to discard the noise.
Signed-off-by: David Brownell <david-b@pacbell.net>
Signed-off-by: Andrew Morton <akpm@osdl.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
|