diff options
author | David S. Miller <davem@davemloft.net> | 2011-04-11 13:44:25 -0700 |
---|---|---|
committer | David S. Miller <davem@davemloft.net> | 2011-04-11 13:44:25 -0700 |
commit | 1c01a80cfec6f806246f31ff2680cd3639b30e67 (patch) | |
tree | 0b554aad2ec1da71ecf6339d4ba51617bfe1dc3c /drivers/hwmon/lm90.c | |
parent | c44d79950b2daa1025e62eede73e4e4a274d1ef3 (diff) | |
parent | 4a9f65f6304a00f6473e83b19c1e83caa1e42530 (diff) |
Merge branch 'master' of master.kernel.org:/pub/scm/linux/kernel/git/davem/net-2.6
Conflicts:
drivers/net/smsc911x.c
Diffstat (limited to 'drivers/hwmon/lm90.c')
-rw-r--r-- | drivers/hwmon/lm90.c | 2 |
1 files changed, 1 insertions, 1 deletions
diff --git a/drivers/hwmon/lm90.c b/drivers/hwmon/lm90.c index 812781c655a..c43b4e9f96a 100644 --- a/drivers/hwmon/lm90.c +++ b/drivers/hwmon/lm90.c @@ -356,7 +356,7 @@ static int lm90_read16(struct i2c_client *client, u8 regh, u8 regl, u16 *value) /* * There is a trick here. We have to read two registers to have the * sensor temperature, but we have to beware a conversion could occur - * inbetween the readings. The datasheet says we should either use + * between the readings. The datasheet says we should either use * the one-shot conversion register, which we don't want to do * (disables hardware monitoring) or monitor the busy bit, which is * impossible (we can't read the values and monitor that bit at the |