summaryrefslogtreecommitdiffstats
path: root/net/8021q/vlan_core.c
diff options
context:
space:
mode:
authorPatrick McHardy <kaber@trash.net>2013-04-19 02:04:27 +0000
committerDavid S. Miller <davem@davemloft.net>2013-04-19 14:45:26 -0400
commitf646968f8f7c624587de729115d802372b9063dd (patch)
tree2b8c6604306f5e74af9e16c17e2b611610982b65 /net/8021q/vlan_core.c
parentc2962897c94605bc8f158a37dee8d867dda9f116 (diff)
net: vlan: rename NETIF_F_HW_VLAN_* feature flags to NETIF_F_HW_VLAN_CTAG_*
Rename the hardware VLAN acceleration features to include "CTAG" to indicate that they only support CTAGs. Follow up patches will introduce 802.1ad server provider tagging (STAGs) and require the distinction for hardware not supporting acclerating both. Signed-off-by: Patrick McHardy <kaber@trash.net> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'net/8021q/vlan_core.c')
-rw-r--r--net/8021q/vlan_core.c4
1 files changed, 2 insertions, 2 deletions
diff --git a/net/8021q/vlan_core.c b/net/8021q/vlan_core.c
index f3b6f515eba..3df29d34470 100644
--- a/net/8021q/vlan_core.c
+++ b/net/8021q/vlan_core.c
@@ -225,7 +225,7 @@ static int __vlan_vid_add(struct vlan_info *vlan_info, unsigned short vid,
if (!vid_info)
return -ENOMEM;
- if (dev->features & NETIF_F_HW_VLAN_FILTER) {
+ if (dev->features & NETIF_F_HW_VLAN_CTAG_FILTER) {
err = ops->ndo_vlan_rx_add_vid(dev, vid);
if (err) {
kfree(vid_info);
@@ -282,7 +282,7 @@ static void __vlan_vid_del(struct vlan_info *vlan_info,
unsigned short vid = vid_info->vid;
int err;
- if (dev->features & NETIF_F_HW_VLAN_FILTER) {
+ if (dev->features & NETIF_F_HW_VLAN_CTAG_FILTER) {
err = ops->ndo_vlan_rx_kill_vid(dev, vid);
if (err) {
pr_warn("failed to kill vid %d for device %s\n",