diff options
Diffstat (limited to 'drivers/cpufreq/cpufreq-dt.c')
-rw-r--r-- | drivers/cpufreq/cpufreq-dt.c | 66 |
1 files changed, 43 insertions, 23 deletions
diff --git a/drivers/cpufreq/cpufreq-dt.c b/drivers/cpufreq/cpufreq-dt.c index f657c571b18..9bc2720628a 100644 --- a/drivers/cpufreq/cpufreq-dt.c +++ b/drivers/cpufreq/cpufreq-dt.c @@ -58,6 +58,8 @@ static int set_target(struct cpufreq_policy *policy, unsigned int index) old_freq = clk_get_rate(cpu_clk) / 1000; if (!IS_ERR(cpu_reg)) { + unsigned long opp_freq; + rcu_read_lock(); opp = dev_pm_opp_find_freq_ceil(cpu_dev, &freq_Hz); if (IS_ERR(opp)) { @@ -67,13 +69,16 @@ static int set_target(struct cpufreq_policy *policy, unsigned int index) return PTR_ERR(opp); } volt = dev_pm_opp_get_voltage(opp); + opp_freq = dev_pm_opp_get_freq(opp); rcu_read_unlock(); tol = volt * priv->voltage_tolerance / 100; volt_old = regulator_get_voltage(cpu_reg); + dev_dbg(cpu_dev, "Found OPP: %ld kHz, %ld uV\n", + opp_freq / 1000, volt); } dev_dbg(cpu_dev, "%u MHz, %ld mV --> %u MHz, %ld mV\n", - old_freq / 1000, volt_old ? volt_old / 1000 : -1, + old_freq / 1000, (volt_old > 0) ? volt_old / 1000 : -1, new_freq / 1000, volt ? volt / 1000 : -1); /* scaling up? scale voltage before frequency */ @@ -89,7 +94,7 @@ static int set_target(struct cpufreq_policy *policy, unsigned int index) ret = clk_set_rate(cpu_clk, freq_exact); if (ret) { dev_err(cpu_dev, "failed to set clock rate: %d\n", ret); - if (!IS_ERR(cpu_reg)) + if (!IS_ERR(cpu_reg) && volt_old > 0) regulator_set_voltage_tol(cpu_reg, volt_old, tol); return ret; } @@ -181,7 +186,6 @@ static int cpufreq_init(struct cpufreq_policy *policy) { struct cpufreq_dt_platform_data *pd; struct cpufreq_frequency_table *freq_table; - struct thermal_cooling_device *cdev; struct device_node *np; struct private_data *priv; struct device *cpu_dev; @@ -210,7 +214,7 @@ static int cpufreq_init(struct cpufreq_policy *policy) priv = kzalloc(sizeof(*priv), GFP_KERNEL); if (!priv) { ret = -ENOMEM; - goto out_put_node; + goto out_free_opp; } of_property_read_u32(np, "voltage-tolerance", &priv->voltage_tolerance); @@ -264,20 +268,6 @@ static int cpufreq_init(struct cpufreq_policy *policy) goto out_free_priv; } - /* - * For now, just loading the cooling device; - * thermal DT code takes care of matching them. - */ - if (of_find_property(np, "#cooling-cells", NULL)) { - cdev = of_cpufreq_cooling_register(np, cpu_present_mask); - if (IS_ERR(cdev)) - dev_err(cpu_dev, - "running cpufreq without cooling device: %ld\n", - PTR_ERR(cdev)); - else - priv->cdev = cdev; - } - priv->cpu_dev = cpu_dev; priv->cpu_reg = cpu_reg; policy->driver_data = priv; @@ -287,7 +277,7 @@ static int cpufreq_init(struct cpufreq_policy *policy) if (ret) { dev_err(cpu_dev, "%s: invalid frequency table: %d\n", __func__, ret); - goto out_cooling_unregister; + goto out_free_cpufreq_table; } policy->cpuinfo.transition_latency = transition_latency; @@ -300,12 +290,12 @@ static int cpufreq_init(struct cpufreq_policy *policy) return 0; -out_cooling_unregister: - cpufreq_cooling_unregister(priv->cdev); +out_free_cpufreq_table: dev_pm_opp_free_cpufreq_table(cpu_dev, &freq_table); out_free_priv: kfree(priv); -out_put_node: +out_free_opp: + of_free_opp_table(cpu_dev); of_node_put(np); out_put_reg_clk: clk_put(cpu_clk); @@ -319,8 +309,10 @@ static int cpufreq_exit(struct cpufreq_policy *policy) { struct private_data *priv = policy->driver_data; - cpufreq_cooling_unregister(priv->cdev); + if (priv->cdev) + cpufreq_cooling_unregister(priv->cdev); dev_pm_opp_free_cpufreq_table(priv->cpu_dev, &policy->freq_table); + of_free_opp_table(priv->cpu_dev); clk_put(policy->clk); if (!IS_ERR(priv->cpu_reg)) regulator_put(priv->cpu_reg); @@ -329,6 +321,33 @@ static int cpufreq_exit(struct cpufreq_policy *policy) return 0; } +static void cpufreq_ready(struct cpufreq_policy *policy) +{ + struct private_data *priv = policy->driver_data; + struct device_node *np = of_node_get(priv->cpu_dev->of_node); + + if (WARN_ON(!np)) + return; + + /* + * For now, just loading the cooling device; + * thermal DT code takes care of matching them. + */ + if (of_find_property(np, "#cooling-cells", NULL)) { + priv->cdev = of_cpufreq_cooling_register(np, + policy->related_cpus); + if (IS_ERR(priv->cdev)) { + dev_err(priv->cpu_dev, + "running cpufreq without cooling device: %ld\n", + PTR_ERR(priv->cdev)); + + priv->cdev = NULL; + } + } + + of_node_put(np); +} + static struct cpufreq_driver dt_cpufreq_driver = { .flags = CPUFREQ_STICKY | CPUFREQ_NEED_INITIAL_FREQ_CHECK, .verify = cpufreq_generic_frequency_table_verify, @@ -336,6 +355,7 @@ static struct cpufreq_driver dt_cpufreq_driver = { .get = cpufreq_generic_get, .init = cpufreq_init, .exit = cpufreq_exit, + .ready = cpufreq_ready, .name = "cpufreq-dt", .attr = cpufreq_generic_attr, }; |